background image

 

 

 

c)  Now add lubricant** to the visible surfaces of both sealing O-rings & the external threads of the head 

connections.  

d)  Place the glass cylinder into one of the head connections, centralizing O-Ring end first. 
e)  Roll the centralising O-Ring down to sit between the precision groove on the head connection and the 

glass cylinder. 

f)  Carefully place the body over the top of the glass cylinder, slipping it down and over until it engages 

with the threaded head connection. 

g)  Loosely thread the body onto the head connection. Do not tighten the two components together, a 

small gap between body & head connection should be visible. 

h)  Fit the final centralizing O-ring into the groove in outstanding head connection. 
i) 

Now add lubricant** to the visible surfaces of the centralizing O-ring. 

j) 

Slip the head connection complete with installed O-Rings over the glass cylinder and tighten loosely. 

k)  Tighten both head connections until they a butted up against the body.  

 
 

** Ensure the lubricant used is not harmful to either the O-rings material or the end users process. 
 

 

 
 
 
 
 
 

 
 

 

 

DANGER 

Adequate PPE should be warn when assembling or disassembling the Hy-

Sight unit, this includes but not limited to eye protection and cut proof gloves. 

 

16633 Foltz Parkway, Strongsville, OH 44149, USA 

 +1  440-572-1500    •   clark-reliance.com 

Summary of Contents for Hy-Sight

Page 1: ...C SIGHT FLOW INDICATORS Installation Operation and Maintenance Manual 16633 Foltz Parkway Strongsville OH 44149 USA 1 440 572 1500 clark reliance com Section T500 Bulletin T500 3 Date 03 16 15 Superse...

Page 2: ...n 2 1 2 Components 3 2 Installation 4 2 1 Unpacking 4 2 2 Visual Inspection 4 2 3 Positioning 4 2 4 Commissioning Start Up 4 3 Maintenance 5 3 1 Disassembly 5 3 2 Assembly 5 16633 Foltz Parkway Strong...

Page 3: ...Operating Temperature F C PSIG Bar g EPDM Silicone FKM Viton FEP Silicone 1 4 300 21 265 129 450 232 400 204 450 232 3 8 300 21 265 129 450 232 400 204 450 232 1 2 300 21 265 129 450 232 400 204 450...

Page 4: ...antity 2 Material 316L Stainless Steel standard options available Glass Cylinder Quantity 1 Material 3 1 Borosilicate Glass standard Acrylic available Sealing O Ring Quantity 2 Material USP Class VI E...

Page 5: ...the life time of the unit it is essential that the unit is not exposed to any of the following a Piping loads or torsional forces the unit is not designed to be load bearing b Sudden increases of pre...

Page 6: ...familiar with this IOM manual The following steps should be taken a Release the tri clamps from both ends of the Hy Sight unit remove the unit as a whole b Unscrew the head connections from the body o...

Page 7: ...mponents together a small gap between body head connection should be visible h Fit the final centralizing O ring into the groove in outstanding head connection i Now add lubricant to the visible surfa...

Reviews: