3-18
Urea(SCR) System (C60-80D, Doosan Engine)
2) Indicator for forced reset
The forklift will turn on the indicator for
forced reset on the dashboard if it is
operated in low load for a long time or if the
reset blocking button is engaged.
The reset has to be started if the icon
flashes, which is called “forced reset”.
CAUTION
!
When the “forced reset” indicator is
on, the operator must engage the
forced reset in 10 hours.
Otherwise, the engine output may be reduced.
The engine output will be reset after the forced reset.
Run the forced reset in the following sequence:
1. Move the forklift to an appropriate place.
2. Set the gear at neutral without turning off the engine and engage
the parking brake.
3. Push and hold the forced reset switch on the right side of the
dashboard in the direction of (1) for more than 3 seconds.
Take the hand off and the switch will return to the original place.
CAUTION
!
Holding the forced reset switch for too long(more than 30
seconds) will fail the engine.
4. The alarm indicator on the right side of
the dashboard will also be lit when the
force reset starts.
CAUTION
!
Make sure NOT to turn of the engine during the reset and
run it in idle mode. Do NOT press the pedal during the
reset. The engine coolant shall be kept hotter than 40°C.
5. The forced reset generally takes 15~20 minutes.
(up to 25 minutes)