INSTALLATION
Before installing your machine, check that its air output is sufficient for the
equipment to be used. The air output from the compressor must be more than
the volume of air required. We recommend the following:
1. 1. Firm and level site, and the use of floor mountings for stationary
compressors - anti-vibration pads. (Do not bolt machines directly to the
floor).
2. Dust and damp free environment.
3. Adequate ventilation for:-
• Air intake to compressor pump (in order to draw in clean air).
• Cooling to compressor pump, and electric motor.
4. To allow sufficient access for servicing, a minimum clearance of 500mm
must be allowed around the machine.
5. The power cable from the main supply must be large enough to carry the
starting and running load of the electric motor. This is particularly relevant if
the compressor is some distance from the source of supply.
6. Electrical installations should be completed by a qualified electrician.
ELECTRICAL CONNECTIONS
Connect the three core mains cable to a suitable industrial supply isolator, or
heavy duty plug meeting the requirements of BS EN 60309. This compressor
must be connected to a supply having a rated capacity of greater than 16
Amps.
A normal 13 Amp (BS1363) plug must NOT be used.
WARNING: THIS APPLIANCE MUST BE EARTHED
.
IMPORTANT: The wires in this mains lead are coloured in accordance with the
following code:
GREEN AND YELLOW - EARTH (E)
BLUE - NEUTRAL (N)
BROWN - LIVE (L)
WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS
SUPPLY.