Clarke Owner's Manual - Vision 38 I/32 I/IX - 26 I/IX
- 21 -
There is no solution flow
.
The solution flow does not stop.
The machine does not remove all the
water from the floor.
The batteries do not give the normal
running time.
Open the solution valve.
Remove the obstruction from the hose and the
filter.
Repair or replace the valve and the linkage.
Fill the solution tank.
Close the solution valve.
Repair or replace the valve and the linkage.
Clean the solution valve.
Replace the seat and washer.
Clean and lubricate valve stem.
Lower the squeegee.
Drain the tank.
Clean the screen filter.
Remove the obstruction or repair the damage.
Check for tripped breaker. Have an autho-
rized service person make repairs.
Connect the hose.
Turn or replace the squeegee blade.
Correctly install the squeegee blade.
Adjust the pressure of the squeegee.
Replace the gaskets.
Clean the terminals and connectors. Replace
the damaged cables. Charge the batteries.
Add distilled water to each cell and charge the
batteries.
Charge the batteries for a full 16 hour charge.
Have an authorized service person repair the
charger.
Check voltage of each cell while discharging.
Connect the batteries.
PROBLEM
CAUSE
ACTION
The solution valve is closed.
There is an obstruction in the solution hose
or filter.
The solution valve or linkage is damaged.
The solution tank is empty.
The solution valve is open.
The solution valve or linkage is damaged.
The solution valve is dirty
There is a damaged seat and washer in the
solution valve.
The valve stem is dirty
The squeegee is up
The vacuum tank is full.
The screen filter is dirty.
There is an obstruction or damage in the
squeegee, squeegee hose or standpipe.
The vacuum motor is not running.
The squeegee hose is disconnected.
The squeegee blade is damaged, worn, or
incorrectly installed.
The squeegee pressure is not correctly
adjusted.
The gaskets on the cover of the recovery
tank are damaged.
The battery terminals are dirty or damaged.
The electrolyte level is too low.
The batteries are not fully charged.
The charger is damaged.
The battery is defective.
The batteries are disconnected.
HOW TO CORRECT PROBLEMS IN THE MACHINE
Summary of Contents for 26I-00260A
Page 29: ...Clarke Owner s Manual Vision 38 I 32 I IX 26 I IX 29 NOTES...