21
TROUBLE SHOOTING
GREEN LED OFF
Fan not operating.
No Input Power.
1.
Plug unit into 230V outlet.
2.
Reset breaker.
GREEN LED ON
YELLOW LED ON
Unit is overheating.
1.
Make sure the unit has not been
operated beyond duty cycle limits.
2.
Air flow obstructed.
GREEN LED ON
YELLOW LED FLASHES
No air flow in purge or pre-flow.
1.
Air not connected or pressure too
low. Check source for at least 5 Bar
(72.5 PSI) during purge or pre-flow,
adjust air pressure to 4,5 Bar (65 PSI).
2.
Air filter or air line blocked, torch
blocked. Contact your clarke
service department to replace the
filter cartridge. Check that air line
and torch leads are free of twists
and kinks.
GREEN LED ON,
YELLOW LED OFF,
No air flow when torch switch pressed.
1.
Shield cup not properly installed
on torch. Check that shield cup is
fully seated against torch.
2.
Faulty Torch Switch.
3.
Faulty Main PC Board Repair /
Replace Power Supply.
GREEN LED ON,
YELLOW LED OFF.
Air flows, Pilot arc does not start.
1.
Faulty torch parts. Inspect torch
parts and replace if necessary.
2.
Gas pressure too high. Set pressure
to 65 psi (4.5 BAR).
3.
Faulty main PC Board. Repair /
replace.
Torch has pilot arc but does not cut.
1.
Work lead not connected. Make
sure work lead is connected
securely to bare metal.
2.
AC input power too low. Use
shortest distance to breaker panel
possible.
3.
Faulty Main PC Board. Repair/
Replace.