background image

OPERATION & MAINTENANCE

INSTRUCTIONS

DL0522 Iss 1

70L INDUSTRIAL DEHUMIDIFIER

MODEL NO: IDH70L

PART NO: 6470613

Summary of Contents for 6470613

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS DL0522 Iss 1 70L INDUSTRIAL DEHUMIDIFIER MODEL NO IDH70L PART NO 6470613 ...

Page 2: ...o their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL RECYCLING POLICY Recycle unwanted materials instead of disposing of them as waste All unwanted accessories and packaging should be sorted and taken to a recycling centre for disposal in a manner which is compatible with the environment By purchasing...

Page 3: ...wiring instructions shown below The old plug must be disposed of safely as insertion we would emphasise the electrical hazard The BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal marked E or or coloured green We strongly recommend that this mac...

Page 4: ...arts clarkeinternational com or Service clarkeinternational com OVERVIEW No Description 1 Handle 2 Control Panel 3 Air Outlet 4 Lifting Handle 5 2 x Wheels 6 2 x Feet 7 16mm x 90cm Drainage Pipe 8 Air Filter Pull Tab 9 Air Inlet and Filter ...

Page 5: ...ble 8 DO NOT install the appliance in rooms containing gas oil or fuel 9 DO NOT install near sources of heat 10 DO NOT use the appliance on inclined surfaces 11 Keep the appliance away from inflammable substances alcohol etc or pressurised containers e g aerosol cans 12 DO NOT rest heavy or hot objects on top of the appliance 13 ALWAYS transport the appliance upright Wait at least 1 hour after tra...

Page 6: ...of possible leaks of refrigerant gas as there could be a danger of fire or explosion hazard should the refrigerant come into contact with electric heaters stoves or other sources of ignition Refrigerant gas may be odourless DO NOT use the product and contact the retailer for advice if damage has occurred to the unit which may have compromised the refrigerant system Any repairs or maintenance must ...

Page 7: ...r using the 4 fixing screws supplied as shown WHEELS 1 Incline the machine body as shown and fix the axle on the bottom of the machine body using the 4 screws 2 Using the nuts and washers fix the wheels to the axle rod 3 Once the wheels have been installed place the machine in the upright position NOTE Once assembly is complete leave the machine to stand for a minimum of 1 hour this is for the ref...

Page 8: ... tank An external prefitted drainage pipe enables continuous dehumidifying without having to empty a water tank Button Operation Instructions On Off Button 4 Switches the machine On and Off Button 6 Adjusts different set values in different states 1 Increases the humidity value set RH 10 to 95 2 Increases the timing Hours set 00 to 24 Button 7 Adjusts different set values in different states 1 Dec...

Page 9: ... Setting the timer for both powering on and off will initiate the cycle timer mode SETTING OF TIMER POWER ON 1 When the machine is powered off press the Timing button 2 The Timing On icon will flicker and the time set will flicker on the display screen 3 Press the or buttons to adjust the timing The dehumidifier will make a sound once the button is pressed The time set will increase or decrease by...

Page 10: ...will enter the continuous dehumidifying mode When started the compressor will start 3 seconds later and when it is shut down the fan will run for 3 seconds If a fault of the humidity sensor occurs the machine will turn to the continuous dehumidifying mode If a fault of the coil sensor occurs the machine will turn to the timing defrosting mode See Defrosting Mode PROTECTION FUNCTION Once shut down ...

Page 11: ...efrosting cycle 2 When ambient temperature is below 25oC but higher than 15o C the compressor will run constantly for 30 minutes it will defrost for 10 minutes of the 30 minute period 3 When ambient temperature is below 15o C but higher than 4oC the compressor will run constantly for 20 minutes it will defrost for 12 minutes of the 20 minute period Temp damp Sensor Fault If the compressor constant...

Page 12: ...ature is too low DO NOT use the dehumidifier Room temperature too high humidity too low In dry conditions the dehumidification ability will reduce Air filter blocked Remove any dirt or obstruction from the air intake Noise is abnormal during operation Dehumidifier is positioned incorrectly Check that dehumidifier is placed on a flat level surface Air filter blocked Remove any dirt or obstruction f...

Page 13: ... RH 60 1300W 30o C RH 80 IP Rating IP22 Dehumidifying Extraction Rate 70 litres day 30oC RH 80 Max Air Flow Rate 400m3 h Operating Temperature 5o C 35o C Refrigerant R290 Hydrocarbon Propane 280g Weight 40 3kg Dimensions LxWxH 545mm x 460mm x 870mm Handle Down 545mm x 460mm x 952mm Handle Up Working Space 50 120m2 Read the manual and safety instructions before use Do not cover when in use Indoor u...

Page 14: ... using the tab 2 Wash the filter under running water to remove any dust and dirt 3 Allow the filter to dry naturally 4 Refitting is the reverse process The frequency depends on the duration and the level of dust in the environment If the machine is being used regularly it is recommended that you clean the filter every 2 weeks STORAGE Unplug from the mains socket Clean and reinstall the filter Cove...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY UKCA CE ...

Page 16: ......

Reviews: