ELECTRICAL CONNECTIONS

Before switching the product on, make sure that the voltage of your electricity supply is 
the same as that indicated on the rating plate. This product is designed to operate on 
230VAC 50Hz. Connecting it to any other power source may cause damage.

This product may be fitted with a non-rewireable plug. If it is necessary to change the 
fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or 
damaged, the plug must not be used until a suitable replacement is obtained.

If the plug has to be changed because it is not suitable for your socket, or due to 
damage, it should be cut off and a replacement fitted, following the wiring instructions 
shown below. The old plug must be disposed of safely, as insertion into a mains socket 
could cause an electrical hazard.

If the colours of the wires in the power cable of this product do not correspond with the 
markings on the terminals of your plug, proceed as follows.

• The wire which is coloured 

Blue

 must be connected to the terminal which is 

marked 

N

 or coloured 

Black

.

• The wire which is coloured 

Brown

 must be connected to the terminal which is 

marked 

L

 or coloured 

Red

.

• The wire which is coloured 

Yellow and Green

 must be connected to the 

terminal which is marked 

or 

 or coloured 

Green

.

We strongly recommend that this machine is connected to the mains supply via a Residual 
Current Device (RCD)

If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself.

WARNING! Read these electrical safety instructions thoroughly 
before connecting the product to the mains supply.

WARNING! The wires in the power cable of this product are 
coloured in accordance with the following code:
Blue = Neutral      Brown = Live     Yellow and Green = Earth

Plug must be BS1363/A approved.

Always fit a 13 Amp fuse.

Ensure that the outer sheath of the cable is firmly held by the clamp

Neutral

(Blue)

Live

(Brown)

Earth

(Green and Yellow)

Summary of Contents for 6933980

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0514 2 5 KW OIL FILLED RADIATOR MODEL NO OFR13 250 PART NO 6933980 ...

Page 2: ... the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment recycling recovery and environmentally sound disposal of the WEEE In effect this means that this product must not be disposed of with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a re...

Page 3: ...r objects at least 50cm from the top and sides and front 13 Do not use this oil filled radiator when it is lying on its side 14 If the oil filled radiator is tipped over unplug it and allow it to cool before standing it back up 15 DO NOT use the oil filled radiator in rooms with explosive gas e g petrol or while using inflammable glue or solvent e g when gluing or varnishing parquet floors PVC etc...

Page 4: ...zard If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connected to the terminal which is marked N or coloured Black The wire which is coloured Brown must be connected to the terminal which is marked L or coloured Red The wire which is coloured Yellow and Green ...

Page 5: ...adiator upside down and insert the securing loop as shown 2 Hook the securing loop to the wheel plate and feed the threaded end of the securing loop through the second hole as shown 3 Fix the wheel plate in position using the wing nut supplied 4 Turn the oil filled radiator the right way up and fit the wheels as shown securing them using the nuts supplied ...

Page 6: ...density fibreboard 1 Turn the thermostat to 0 before plugging in the radiator 2 Plug the radiator into the mains supply 3 Use the power switches to turn the radiator on NOTE The first time the radiator is used there may be an odour that will disappear after approximately 30 minutes of operation The odour is due to a lubricant used during the manufacture of the radiator CAUTION DO NOT OPERATE THE R...

Page 7: ... switch which turns off the oil filled radiator if it falls over simply stand the radiator up again to reset this switch The second is a safety overheat device which switches off the oil filled radiator in the event of overheating caused by any fault condition which induces a rapid temperature rise In the event of the safety overheat device operating the oil filled radiator will cease to function ...

Page 8: ...ional com or Service clarkeinternational com SPECIFICATION Model Number OFR13 250 Operating Voltage and Frequency 230 V 50 Hz Input Power 2500 W Number of segments 13 Class of Protection 1 IP Rating IP20 Dimensions L x W x H 580 x 250 x 630 mm Weight 15 3 Kg ...

Page 9: ... of the oil filled radiator to remove dust and dirt 4 Ensure the oil filled radiator is dry before plugging back into the mains supply 5 Do not allow water to run into the interior of the oil filled radiator as this could create a fire or electric shock hazard STORAGE If the oil filled radiator is not going to be used for long periods for example during the summer it should be stored in a dry plac...

Page 10: ...10 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com NOTES ...

Page 12: ......

Reviews: