13
OPERATING INSTRUCTIONS
Switching the air compressor ON
The compressor will make a continuous loud noise when the tank is charging -
this is normal.
1
Lift the red On/Off switch located on top of the pressure regulator and cut-
out.
•
The compressor will charge the main tank to 10 bar (145 psi) then switch
off.
•
The compressor will restart automatically whenever the pressure in the
main tank falls below a certain level.
2
Check the operation of the safety
valve, under pressure, daily by pulling
the ring as shown in figure 6. Air should
be released you pull the ring and stop
when the ring is released.
•
If the valve does not operate as
described, or if the valve is stuck, it
must be replaced by qualified
service personnel before using the
compressor.
WARNING!
Do not remove or attempt to adjust the safety valve.
3
Select the pressure you need using
the pressure regulator. See figure 7.
4
Open the outlet tap.
Figure 7
Figure 6
Pressure
regulator
Output pressure
gauge
Outlet
Tap