12
-
Parts List - Pump
No.
Description
Qty
Part No
1
Intake Filter
1
FN317028000
2
Head
1
FN1160060031
3
Screw
4
FN014013027
4
Head Gasket
1
FN115005017
5
Valve Plate
1
FN416005009
6
‘O’ Ring
1
FN010057000
7
Cylinder
1
FN016005007
8
Con-Rod Assy
1
FN416005003
9
Bearing
1
FN033059000
10
Impeller
1
FN116010004
11
Washer
1
FN116010013
12
Screw
1
FN014001022
13
Crankshaft
1
FN116010006
14
Casing
1
FN015010025
15
Screw
3
FN014002122
16
Bearing
1
FN033028000
17
Armature
1
FN034128000
18
Stator
1
FN316008604
19
Bearing
1
FN033070000
20
Balancing Ring
1
FN027011000
21
Rear Frame
1
FN116010016
22
Nut
3
FN014004001
23
Overload Reset
1
FN008040000
24
Capacitor
1
FN009200004
Electrical Connections
This product is provided with a standard 13 amp, 230 volt (50Hz), BS 1363 plug, for connection
to a standard, domestic electrical supply. Should the plug need changing at any time,
ensure that a plug of identical specification is used.
WARNING! THIS APPLIANCE MUST BE EARTHED
Should the plug need changing at any time, ensure that a plug of identical specification
is used. IMPORTANT: The wires in the mains lead should be wired up in accordance with
the following colour code:
Green & Yellow ..................... Earth
Blue ......................................... Neutral
Brown ..................................... Live
•
Connect the
Green & Yellow
coloured cord to the plug terminal marked a
letter “ E ”or marked with the symbol “ ”
•
Connect the BLUE coloured cord to the plug terminal marked a letter “N”
•
Connect the BROWN coloured cord to the plug terminal marked a letter “L”
FUSE RATING
The fuse in the plug must be replaced with one of the same rating
(13amps)
and this
replacement must be ASTA approved to BS1362.
We recommend that this machine is connected to the mains supply via a Residual Current
Device (RCD)
If in doubt, consult a qualified electrician. Do not attempt any electrical repairs yourself.
CABLE EXTENSION.
Always use an approved cable extension suitable for the power rating of this tool (see
specifications), the conductor size should also be at least the same size as that on the
machine, or larger. When using a cable reel, always unwind the cable completely.
If this appliance is fitted with a plug which is
moulded on to the electric cable (i.e. non-
rewireable) please note:
1.
The plug must be thrown away if it is cut from
the electric cable. There is a danger of
electric shock if it is subsequently inserted
into a socket outlet.
2.
Never use the plug without the fuse cover
fitted.
3.
Should you wish to replace a detachable
- 5 -
fuse carrier, ensure that the correct replacement is used (as indicated by marking or
colour code).
4.
Replacement fuse covers can be obtained from your local Clarke dealer or most
electrical stockists.