EN
ENGLISH
- 8 - FORM NO. 70880A
Clarke
®
Operator's Manual (EN) - CFP Polisher
120 VOLT MACHINES
Instructions for connection to the power supply and the electrical ground.
This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current
to reduce the risk of electrical shock. This product is equipped with a cord having an equipment-grounding conductor and grounding
plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes
and ordinances.
WARNING: Improper connection of the equipment-grounding conductor can result in a risk of
electric shock. Check with a quali
fi
ed electrician or service person if you are in doubt as to whether
the outlet is properly grounded. Do not modify the plug provided with the product - if it will not
fi
t the
outlet, have a proper outlet installed by a quali
fi
ed electrician.
This product is for use on a nominal 120 volt circuit and has a grounding attachment plug that looks like the plug illustrated in Fig. 3.
Make sure that the product is connected to an outlet having the same con
fi
guration as the plug. No adaptor should be used with this
product.
WARNING: To prevent possible electric shock, protect the machine from rain. Keep the machine
in a dry building.
WARNING: To prevent possible electrical shock, always use a 3-wire electrical system connected
to the electrical ground. For maximum protection against electrical shock, use a circuit that is pro-
tected by a ground fault circuit interrupter. Consult your electrical contractor.
WARNING: Do not cut, remove or break the ground pin. If the outlet does not
fi
t the plug, consult
your electrical contractor.
WARNING: Have worn, cut or damaged cords replaced by an authorized service person.
EXTENSION CORDS
Use only an approved extension cord with three conductors, a plug with three terminals, and a connector body with three holes. The
machine has a power cord with wire size 14 AWG (AWG means American Wire Gauge).
WARNING: If you use an extension cord, use an extension cord with minimum wire size 12 AWG. Do
not use an extension cord longer than 50 feet. Do not join two extension cords.
Figure 3
Grounding Pin
Adapte
Metal Scre
Grounded Outlet Box
Grounded Outlet
revised 11/13