Item

Symbol

Value

Unit

Heat output

Measured seasonal space heating energy efficiency

36%

Nominal heat output

P

nom

30

kW

Minimum heat output (indicative)

min

15

kW

Maximum continuous heat output

max

30

kW

Auxiliary electricity consumption

At nominal heat output

el

max

n/a

kW

At minimum heat output

el 

min

n/a

kW

In standby mode

el

SB

n/a

kW

Type of heat input for electric storage local heaters only

Manual heat charge control with integrated thermostat

n/a

Manual heat charge control with room and/or outdoor temperature 
feedback

n/a

Electronic heat charge control with room and/or outdoor temperature 
feedback

n/a

Fan assisted output

n/a

Type of heat output/room temperature control (select one)

Single stage heat output, no temperature control

No

Two or more manual stages, no temperature control

No

With mechanical thermostat temp control

Yes

With electronic temperature control

No

Electronic temperature control with day timer

No

Electronic temperature control with week timer

No

Other control options (multiple selections possible)

Room temperature control with presence detection

No

Room temperature control with open window detection

No

Room temperature control with distance control option

No

Room temperature control with adaptive start control

No

Room temperature control with working time limitation

No

Room temperature control with black bulb sensor

No

Summary of Contents for DEVIL 7003

Page 1: ...his product is only suitable for well insulated spaces or occasional use OPERATION MAINTENANCE INSTRUCTIONS LS0618 ISS 5 ORIGINAL INSTRUCTIONS 30KW ELECTRIC FAN HEATER MODEL NO DEVIL 7030 PART NO 6935458 ...

Page 2: ...t used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights LIST OF CONTENTS ENVIRONMENTAL RECYCLING POLICY Through purchase of this product the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulatio...

Page 3: ...room and or outdoor temperature feedback n a Electronic heat charge control with room and or outdoor temperature feedback n a Fan assisted output n a Type of heat output room temperature control select one Single stage heat output no temperature control No Two or more manual stages no temperature control No With mechanical thermostat temp control Yes With electronic temperature control No Electron...

Page 4: ...lator into the main distribution board Make sure that the voltage on the rating plate is the same as the voltage of the power supply If in doubt consult a qualified electrician Do not abuse the electrical cable Never use the cable for pulling or unplugging the heater Keep the cable away from sources of heat oil sharp edges or moving parts Damaged or tangled cables increase the risk of electric sho...

Page 5: ...e DO NOT place the heater up against any surface such as a wall door or furniture etc DO NOT place the heater immediately below any electrical outlet NEVER place the heater near combustible materials such as curtains furniture etc Allow at least 2 metre clearance DO NOT place the heater on a raised surface or anywhere where it could topple over Take care to ensure that the grille cannot be blocked...

Page 6: ...be kept away unless continuously supervised OPERATION The heater must only be used by people who have read these instructions and have been trained in its use DO NOT obstruct the air inlet and outlet sections of the heater DO NOT cover the heater DO NOT touch the heater casing or grille when first switched off as these will be very hot and will take time to cool DO NOT get the heater wet or use in...

Page 7: ...60309 A length of 2 3 metres is recommended giving mobility to the appliance but without becoming a trip hazard If in any doubt consult a qualified electrician DO NOT attempt any electrical work yourself SAFETY SYSTEMS THERMOSTATIC PROTECTION The Devil 7030 has a thermal cut out to prevent the unit from overheating If the temperature of the front grille gets too high the thermal cutout will turn o...

Page 8: ...TE The bolt needs to be inserted before the handwheel NOTE The bolt goes through the larger of the 2 holes in the spacer 2 Fit the axle and left hand support frame NOTE The circlip shown must be on the inside of the legs 3 Fit the wheels as shown NOTE The cap fits over the flat washer 4 Use the nuts and bolts supplied to secure the handle to the leg frames as shown ...

Page 9: ...ture 5 Once the room reaches the required temperature turn the thermostat control slowly counter clockwise until the thermostat clicks leave the control in this position The room temperature will be maintained at this setting The heater will continue to operate until the power switch is turned to the OFF position WARNING DO NOT USE THIS HEATER IN SMALL ROOMS WHEN THEY ARE OCCUPIED BY PERSONS NOT C...

Page 10: ... of the case and elements Once the fan stops you can safely remove the plug from the power supply 8 When not in use disconnect the heater from the mains supply Store it in a safe dry childproof location MAINTENANCE Clean the heater with a soft damp cloth Do not use solvents or abrasives Make sure that the heater grill is not blocked No other maintenance is required should you discover any problem ...

Page 11: ...g Voltage Current and Frequency V A Hz Phs 400 V 43A 50Hz 3 Phase Operating Temperature Min Max C 0 40 C Heat Output kW 30 kW Air Output m3 h 1440m3 h Safety Device Thermal cut out Duty Cycle Classification Continuous duty Electrical Insulation Class I Product Depth x Width x Height 640 x 610 x 1012 mm Product Weight 30 45 kg ...

Page 12: ...ket outlet Insert the plug in a suitable socket Heating element glowing hot Input voltage too high or too low Use a power supply in accordance with the rating on the label Air inlet grille is blocked Ensure the heater is kept away from any objects which could cover the air inlet or be drawn into it The unit has failed to heat up so only the air fan has operated Control switch not set at a HEATING ...

Page 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM ...

Page 14: ...r 33 Heater Bracket Bottom 9 Fasten Spring 34 Wheel 10 Thermostat Knob 35 Wheel Cover 11 Control Box L 36 Securing Plate 12 Control Box Cover 37 Axle 13 Control Box R 38 Base Pad 14 Cable Inlet Gland 39 Rear Frame 15 Sealing Tape 40 Adjustable Screw 16 Overheat Thermostate 41 Spacer 17 After Cooling Thermostate 42 Securing Plate L 18 Chassis Panel 43 Securing Plate 19 Motor Capacitor 44 Rivet Nut ...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Page 16: ......