FORM NO. - 56091028 - FOCUS
®
II LARGE -
A-17
ENGLISH / A-17
SERVICING THE RECOVERY TANK SWITCH
If the recovery tank
fl
oat switch becomes dirty it can impair its proper operation. A dirty vacuum shut off switch can cause the vacuum motor to not
function at all or to not shut off when the tank is full.
If daily rinsing of the recovery tank does not suf
fi
ce to keep the switch clean you may need to disassemble it for cleaning. It is very important that
it be reassembled correctly in order to function. See Figure 5 for the correct orientation of the switch
fl
oat arm.
Refer to the service manual for detailed disassembly and cleaning instructions.
FIGURE 5
Float should move up & down freely.
Factory installed Vacuum Shut-Off Switch. Float on BOTTOM.
OFF
ON