background image

4

SAFETY INSTRUCTIONS

KEEP CHILDREN AWAY: 

Do not allow children to touch the puddle pump, cables

or connections. Visitors should be kept away from the work area.

STORE IDLE TOOLS:

 When not in use, the puddle pump should be stored in a dry,

secure place out of the reach of children.

DISCONNECT TOOLS: 

Disconnect the puddle pump from the mains supply when

not in use, or when making adjustments etc.

REPAIRS: 

Have the puddle pump repaired by a qualified person.

STAY ALERT: 

Watch what you are doing. Use common sense and caution. Never

operate the puddle pump when you are tired.

DO NOT ABUSE THE MAINS LEAD: 

Never carry the puddle pump by the mains

lead or pull it to disconnect it from the mains socket. Keep the mains lead away
from heat, oil and sharp edges. Always check the plug, mains cable and float
switch cable for damage prior to use. Do NOT use if damaged. Refer to
qualified service personnel for repair. If you have to use an extension lead with
this product, it must be designed for outdoor use and incorporate a cable
suitable for use with Class I appliances.

USE A RESIDUAL CURRENT DEVICE: 

To provide personal protection against

harmful electric current, the puddle pump must be supplied through a high
sensitivity residual current device (RCD) with a rated residual operating current
not exceeding 30mA.

POWER LEAD:

 If you need to lower the pump into a shaft or well, Tie rope round

the handle and lower the pump using the rope. Do not lower the pump using
the mains lead.

SWIMMING POOLS: 

If the pump is being used to drain swimming pools, ensure

thet no children or animals are in the pool whenever the pump is being used.

Summary of Contents for PSP125

Page 1: ...PUDDLE PUMP PUDDLE PUMP MODEL No PSP125 Part No 7230692 OPERATION MAINTENANCE INSTRUCTIONS 0308 ...

Page 2: ...4 83 kg with cable Part Number 7230692 Please note that the details and specifications contained herein are correct at the time of going to print However CLARKE International reserve the right to change specifications at any time without prior notice Always consult the machine s data plate When disposing of this product do not dispose of with general waste It must be disposed of according to the l...

Page 3: ...the safety of yourself and that of others around you and you can look forward it giving long and satisfactory service GUARANTEE This CLARKE product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your receipt as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for...

Page 4: ... lead away from heat oil and sharp edges Always check the plug mains cable and float switch cable for damage prior to use Do NOT use if damaged Refer to qualified service personnel for repair If you have to use an extension lead with this product it must be designed for outdoor use and incorporate a cable suitable for use with Class I appliances USE A RESIDUAL CURRENT DEVICE To provide personal pr...

Page 5: ...minal marked with a letter N or coloured BLACK If this appliance is fitted with a plug which is moulded onto the electric cable i e non rewireable please note 1 The plug must be thrown away if it is cut from the electric cable There is a danger of electric shock if it is subsequently inserted into a socket outlet 2 Never use the plug without the fuse cover fitted 3 When replacing a detachable fuse...

Page 6: ...6 PARTS IDENTIFICATION Suction Base Carry Handle Motor Housing Multi hose fitting Water Outlet Control Switch Automatic A Manual M Open O See Maintenance ...

Page 7: ... 3 mm Note always consider the outlet hose diameter Swimming pool water Note After pumping chlorinated water or other liquids containing additives the pump should be thoroughly rinsed with clean water Soapy water Liquids that MUST NOT be pumped are Corrosive substances Combustible or explosive substances petrol thinners etc Fats oils or salts Waste from toilets or urinals This puddle pump is not d...

Page 8: ...n adapters If you wish to connect a 1 hose using a hose clip simply attach it to the end of the adapter If you wish to use a 1 BSP hose adapter for 1 dia hose cut the multi hose adapter at point A If you wish to connect a 1 1 4 hose using a hose clip cut the adapter at point B If you wish to use a 1 1 4 BSP hose adapter for 1 1 4 dia hose cut the multi hose adapter at point C We strongly recommend...

Page 9: ...ection against harmful electric current 4 Switch the mains power supply on and place the pump into the water you want to drain The pump will automatically switch on whenever the water depth is above 85 mm 5 The pump will begin to drain water to a predetermined depth of 25mm 6 To drain down further to a height of 2 3 mm or if the water depth is less then 85 mm set the control switch to the M manual...

Page 10: ...c l a m r e h T o t e u d d e t a v i t c a g n i t a e h r e v o r e w o P o N n e h t l o o c o t w o l l A s n i a m e h t m o r f t c e n n o c s i d o n e r a e r e h t t a h t e r u s e k a M s e g a k c o l b l a c i r t c e l e d n a s e s u f k c e h C s n o i t c e n n o c t u b s n u r p m u P y l n e d d u s t u p t u o s e s a e r c e d d e g g o l c s i e s a B s n i a m e h t m o r ...

Reviews: