background image

2

INTRODUCTION

Thank you for purchasing this CLARKE Silent Air Compressor.

Before attempting to use this product, please read this manual thoroughly and 
follow the instructions carefully. In doing so you will ensure the safety of yourself 
and that of others around you, and you can look forward to your purchase 
giving you long and satisfactory service.

GUARANTEE

This product is guaranteed against faulty manufacture for a period of 12 
months from the date of purchase. Please keep your receipt which will be 
required as proof of purchase. 

This guarantee is invalid if the product is found to have been abused or 
tampered with in any way, or not used for the purpose for which it was 
intended.

Faulty goods should be returned to their place of purchase, no product can 
be returned to us without prior permission. 

This guarantee does not effect your statutory rights.

PARTS AND SERVICING

For Parts & Servicing, please contact your nearest dealer, or 

CLARKE International, on one of the following numbers.

PARTS & SERVICE TEL: 020 8988 7400

PARTS & SERVICE FAX: 020 8558 3622

or e-mail as follows:

PARTS: Parts@clarkeinternational.com

SERVICE: Service@clarkeinternational.com

Summary of Contents for SHHHAIR 50/24

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS 0309 SILENT AIR COMPRESSOR MODEL NO SHHHAIR 50 9 PART NO 2320870 ...

Page 2: ...eep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights PARTS AND SERVICI...

Page 3: ...eep clear of any possible source of ignition 11 Protect yourself Think carefully about any potential hazards which may be created by using the air compressor and use the appropriate protection e g Goggles will protect your eyes from flying particles Face masks will protect you against paint spray and or fumes 12 Before spraying any material always consult paint manufacturers instructions for safet...

Page 4: ... fitted with a plug which is moulded onto the electric cable i e non rewireable please note 1 The plug must be thrown away if it is cut from the electric cable There is a danger of electric shock if it is subsequently inserted into a socket outlet 2 Never use the plug without the fuse cover fitted 3 When replacing a detachable fuse carrier ensure the correct replacement is used as indicated by mar...

Page 5: ...wn on the data label on the side of the compressor The ON OFF switch is in the OFF position Remove any transit caps from the air inlets and replace them with the air inlet filters supplied ADDING OIL The compressor is supplied without any oil inside 1 Make sure that the oil level is half way up the oil sight glass 2 If not remove the oil cap and top up the reservoir Only use Clarke synthetic compr...

Page 6: ...ht If you release air by opening the air outlet tap the motor will start automatically once the cut in pressure is reached 2 A B C D E Allow the compressor to run for 10 15 seconds with the air outlet tap A open This will distribute the lubricating oil 3 Close the outlet tap and connect a suitable air hose to the filter regulator outlet B Connect the other end to the equipment to be used 4 Check t...

Page 7: ...set open the air outlet tap NOTE If the machine pumps continuously without cutting out then the compressor is too small for the application tool being used and damage may result Consult your Clarke dealer NOTE DO NOT exceed the duty cycle for the machine see Specifications SHUTTING DOWN THE COMPRESSOR 1 To shut off the compressor simply turn the ON OFF switch to the O OFF position 2 Close the air ...

Page 8: ...the compressor to the sink and place the free end of the small hose in the sink 4 Slowly open the vent valve 5 When the reservoir has been drained re tighten the vent valve and remove the hose DRAINING THE AIR OUTLET FILTER 1 Valve E Drain any liquid that may have accumulated in the air filter chamber by first twisting and then pushing the valve E upwards ...

Page 9: ...ssible that you are trying to use more air than the compressor is capable of delivering Renew oil filler air Filter plug Air leaking from the pressure switch valve when the compressor is not running Faulty non return valve First drain the receiver completely of air Renew the non return valve Air pressure from the regulator will not adjust The diaphragm within the regulator body is broken Replace r...

Page 10: ... Check the safety valve pulling the ring gently when there is pressure in the tank X Total replacement of oil See Drain and replace the oil on page 10 X DRAIN AND REPLACE THE OIL Drain and replace the oil annually as follows 1 Remove the 4 hex head screws securing the compressor head 2 Pull off the head complete with sealing ring 3 Tilt the compressor carefully on to its side so that the oil is dr...

Page 11: ...e connection and disassemble it as shown 3 Clean all the components with a dry cloth and reassemble the valve taking care to place the internal rubber disc 2 as shown 4 Fasten the valve to the connection and join the flexible hose If the leakage persists the whole valve must be replaced REPLACING THE AIR OUTLET FILTER NOTE The compressor must be completley depressurised before carrying out this pr...

Page 12: ... No 2320870 Dimensions L x H x W 330 x 470 x 330 mm Sound Power Level 40dBA Weight 21 kg Compressor Oil 500mL Synthetic Oil Oil Part No 3050795 Please note that the details and specifications contained herein are correct at the time of going to print CLARKE International reserve the right to change specifications at any time without prior notice ...

Page 13: ...13 EXPLODED DIAGRAM PARTS LIST ...

Page 14: ...14 EXPLODED DIAGRAM PARTS LIST ...

Page 15: ...Filter C2083 Capacitor C0046 Non Return Valve M F 1 8 C0047 Quick Coupling M5X 6 C0051 Rylsan Hose 4 6 C0077 Swivel Connector M1 4 C0082 Pressure 1 WAY C0083 Connection M 1 4 L 80 C0089 Nipple 1 4 L 95 C0091 Electric Cable MM 500 C0348 T Connection F F F 1 4 C0133 Electric Cable 3X0 75 L 2500 230V C2376 Filter Regulator C0297 Air Hose C0301 Exhaust Valve C0334 Distribution Frame L M F 1 8 CH13 C03...

Page 16: ...re Equipment The Following Standards have been applied to the product BS EN 10121 96 BS EN 292 1 91 BS EN 292 2 91 BS EN 60204 1 98 BS EN 55014 1 2001 EN 61000 3 2 2001 The technical documentation required to demonstrate that the products meet the requirements of the Low Voltage Equipment directive has been compiled and is available for inspection by the relevant enforcement authorities The CE mar...

Page 17: ...17 NOTES ...

Page 18: ...18 NOTES ...

Page 19: ...19 NOTES ...

Page 20: ......

Reviews: