9
TROUBLESHOOTING
PROBLEM
PROBABLE CAUSE
REMEDY
The compressor will not start,
or stops and will not start
again
Bad connections
Check the electrical
connections
Blown fuse
Replace fuse
Overload cutout switch has
tripped
Wait 25-20 mins before
attempting to restart
Compressor does not start
Air receiver charged
Open drain valve to
expel air. Compressor
should start again
when pressure
reduces to approx 95
psi
The compressor does not
reach the set pressure and
overheats easily
Inlet Air Filter is blocked
NOTE: It is also possible that
you are trying to use more
air than the compressor is
capable of delivering
Renew oil filler/air Filter
plug
Air leaking from the pressure
switch valve when the
compressor is not running
Faulty non-return valve
First drain the receiver
completely of air.
Renew the non-return
valve
Air pressure from the
regulator will not adjust.
The diaphragm within the
regulator body is broken
Replace regulator
Compressor operating, but
no air from outlet
Inlet air filter blocked
Renew oil filler/air filter
plug
Pressure regulator closed
Turn Regulator
clockwise to set
required pressure
Drain valve open
Close vent valve
Bleed pipe (from Pressure
Switch to non-return valve)
broken or disconnected
Reconnect or replace
bleed pipe