background image

6

TROUBLE SHOOTING

If the system is set up properly, there is little likelihood of problems arising, but if
water will not flow as it should then check the following points:-

1.

If using a suction lift, the suction hose and connections need to be completely
air tight, otherwise air will be drawn in and either reduce or completely stop
the flow of water.

Additionally, ensure that the system has been fully primed with water up to
the top lip of the outlet port adapter.

2.

Check to see that no foreign matter is fouling the intake system - check the
strainer is not blocked or obstructed.

Should you still experience problems, then contact your Clarke dealer, or CLARKE
International Service Department for advice.

Please contact your nearest dealer, or

CLARKE International, on one of the following numbers.

PARTS & SERVICE TEL:  020 8988 7400

PARTS & SERVICE FAX:  020 8558 3622

or    e-mail as follows:

PARTS:   Parts@clarkeinternational.com

SERVICE:    Service@clarkeinternational.com

ACCESSORIES

Foot Valve Filter Brass ....................................................................... 7950561

1” I.D. Reinforced Hose for suction and delivery. ......................... 7955010

Water Filter ......................................................................................... 7175100

Water Filter cartridge ........................................................................ LDCF10

SPARE PARTS & SERVICING

Summary of Contents for SPP3

Page 1: ...OPERATING MAINTENANCE INSTRUCTIONS POND PUMP Model Nos SPP3 SPP6 0200 ...

Page 2: ... effect your statutory rights SAFETY PRECAUTIONS 1 Ensure the pump is installed in a horizontal position with the outlet facing vertically upwards and that it is firmly anchored via its fixing screws 2 Ensure there is an adequate air flow around the pump DO NOT mount it in an enclosed atmosphere 3 Ensure all water pipes supply or discharge are adequately supported where necessary so as not to put ...

Page 3: ...l marked with N or coloured BLACK If this appliance is fitted with a plug which is moulded onto the electric cable i e non rewirable please note 1 The plug must be thrown away if it is cut from the electric cable There is a danger of electric shock if it is subsequently inserted into a socket outlet 2 Never use the plug without the fuse cover fitted 3 Should you wish to replace a detachable fuse c...

Page 4: ...sition i e with the outlet port see Fig 1 facing vertically upwards The fixing slots in the base should be used as necessary to secure the pump firmly in its operating position Also ensure that there is adequate air circulation around the motor Avoid situations where there is the risk of water coming into contact with the outside of the pump Neither the motor or the terminal box are intended to be...

Page 5: ... Clarke International Service Department for advice B GRAVITY FEED Do not place any restriction on the inlet side of the pump The delivery head i e the vertical distance between the pump outlet and the point of discharge should not exceed distance specified for your pump see Specifications page 7 To prevent unnecessary strain or possible distortion to the pump ensure that adequate support is provi...

Page 6: ... 2 Check to see that no foreign matter is fouling the intake system check the strainer is not blocked or obstructed Should you still experience problems then contact your Clarke dealer or CLARKE International Service Department for advice Please contact your nearest dealer or CLARKE International on one of the following numbers PARTS SERVICE TEL 020 8988 7400 PARTS SERVICE FAX 020 8558 3622 or e m...

Page 7: ... Max Output 60 L min 3 6M3 h 100 L min 6M3 h Insulation Rating IP44 IP44 Dimensions LxWxH 255x150x190mm 255x150x190mm Part No 7175010 7175020 NOTE As the pumping head is increased so the flow rate of water will decrease Please note that the details and specifications contained herein are correct at the time of going to print However CLARKE International reserve the right to change specifications a...

Page 8: ...PARTS DIAGRAM 8 ...

Page 9: ...P1240012 6 Sealing ring LDP1200027 7 Gasket LDS3500199 8 Terminal box LDS3500214 9 Capacitor LDP1360009 10 Screw LDP1100004 11 Seal LDP1200021 12 Screw LDP1100006 13 Cover LDP3500218 14 Screw LDP1100006 15 Washer LDP1120003 16 Cable clamp LDP1510004 17 Switch assembly LDP1380001 18 Power Cable LDP1330013 19 Nut LDP1510009 20 Cable Gland LDP1230001 21 Motor Assembly n a 9 ...