ELECTRICAL CONNECTIONS

Before switching the product on, make sure that the voltage of your electricity supply is 
the same as that indicated on the rating plate. This product is designed to operate on 
230VAC 50Hz. Connecting it to any other power source may cause damage.

This product may be fitted with a non-rewireable plug. If it is necessary to change the 
fuse in the plug, the fuse cover must be refitted. If the fuse cover becomes lost or 
damaged, the plug must not be used until a suitable replacement is obtained.

If the plug has to be changed because it is not suitable for your socket, or due to 
damage, it should be cut off and a replacement fitted, following the wiring instructions 
shown below. The old plug must be disposed of safely, as insertion into a mains socket 
could cause an electrical hazard

.

If the colours of the wires in the power cable of this product do not correspond with the 
markings on the terminals of your plug, proceed as follows.

• The wire which is coloured 

Blue

 must be connected to the terminal which is 

marked 

N

 or coloured 

Black

.

• The wire which is coloured 

Brown

 must be connected to the terminal which is 

marked 

L

 or coloured 

Red

.

• The wire which is coloured 

Yellow and Green

 must be connected to the terminal 

which is marked 

or 

 or coloured 

Green

.

We strongly recommend that this machine is connected to the mains supply via a Residual 
Current Device (RCD)

If in any doubt, consult a qualified electrician. DO NOT attempt any repairs yourself

WARNING: READ THESE ELECTRICAL SAFETY INSTRUCTIONS 
THOROUGHLY BEFORE CONNECTING THE PRODUCT TO THE MAINS 
SUPPLY.

WARNING: THE WIRES IN THE POWER CABLE OF THIS PRODUCT ARE 
COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:
BLUE = NEUTRAL      BROWN = LIVE     YELLOW AND GREEN = EARTH

Plug must be BS1363/A approved.

Always fit a 5 Amp fuse.

Ensure that the outer sheath of the cable is firmly held by the clamp

Neutral

(Blue)

Live

(Brown)

Earth

(Green and Yellow)

Summary of Contents for YDH30

Page 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0916 30 LITRE DEHUMIDIFIER MODEL NO YDH30 PART NO 6479600 ...

Page 2: ...r the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory rights ENVIRONMENTAL PROTECTION Through purchase of this product the customer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment ...

Page 3: ...lling the power cable 8 Do not install the appliance in rooms containing gas oil or sulphur Do not install near sources of heat 9 Do not use the appliance on inclined surfaces 10 Keep the appliance at least 50 cm away from curtains inflammable substances alcohol etc or pressurised containers e g aerosol cans 11 Do not rest heavy or hot objects on top of the appliance 12 Always transport the applia...

Page 4: ...azard If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connected to the terminal which is marked N or coloured Black The wire which is coloured Brown must be connected to the terminal which is marked L or coloured Red The wire which is coloured Yellow and Green...

Page 5: ...ck the air flow Make sure that the power cable is not placed where it can be inadvertently pulled or pinched and where it does not cause a trip hazard Do not place the dehumidifier next to a radiator or other heat source as this will reduce the performance of your dehumidifier To maximise efficiency do not open any doors or windows during use Wait at least 1 hour after transporting the appliance b...

Page 6: ...buttons at the same time Used to adjust the humidity setting from 40 70 default 50 Turns the dehumidifier on or off Set the number of hours until the dehumidifier is turned on or off Selects the operating mode also activates the child lock Starts or stops the swing function Ultra quiet fan mode ideal for overnight use Activate the ionizer function Activate the internal drying function ...

Page 7: ...ress the POWER button to switch the dehumidifier ON The dehumidifier will run in the last mode selected 3 Press the POWER button again to switch the dehumidifier OFF CHILD LOCK The child lock is used to disable the function keys to prevent accidentally changing the settings TURNING ON 1 Press and hold the MODE button for 2 seconds to turn the child lock on The child lock symbol will be shown in th...

Page 8: ...will show the selected number of hours flashing on and off for 5 seconds and then stop flashing 2 To cancel the timer function press the TIMER key once more TIMER OFF SETTING AUTO STOP 1 While the dehumidifier is running Press TIMER key repeatedly to set the length of time 1 24 hours until the dehumidifier turns off The display will show the selected number of hours flashing on and off for 5 secon...

Page 9: ...The dehumidifier will run continuously at high speed regardless of the current humidity level Mild Dehumidification The dehumidifier will run continuously at low speed regardless of the current humidity level Air Purification The dehumidifier function is switched off and the fan will run continuously through the filter Fit the filter See page 10 before using this mode Press the humidity button to ...

Page 10: ...E THE IONIZER FUNCTION 1 Press the IONIZER button A leaf symbol will appear on the display to show the ionizer function is active The swing function can also be used to adjust the position of air outlet grill FITTING REMOVING THE FILTER 1 Remove the front panel 2 Remove the plastic filter 3 Insert the filter into the framework Make sure that the front of the filter is facing towards you An optiona...

Page 11: ...tched on and the water tank is removed or fitted incorrectly 3 Remove the water tank lid and discard the water 4 Replace the lid and refit the water tank NOTE The unit will not operate unless the water tank is fitted correctly CONTINUOUS DRAINING This function enables continuous dehumidifying without having to empty the water tank 1 Remove the knock out section in the case using a small screwdrive...

Page 12: ...period of time Running the cycle will remove water moisture from the unit preventing a build up of mildew which will affect the efficiency and life of the unit HOW TO START THE DRYING FUNCTION 1 Press and hold the Drying button for 2 seconds until DRYING FUNCTION is selected HOW TO STOP THE DRYING MODE 1 Press and hold the Drying button for 2 seconds to cancel the drying function The unit will be ...

Page 13: ... finish CLEANING THE FILTERS PLASTIC FILTER 1 Remove the front panel 2 Remove the plastic filter 3 Rinse the filter under warm water 4 Allow the filter to dry naturally 5 Refit parts in the reverse order The frequency depends on the duration of use and the level of dust in the environment CARBON HEPA FILTERS The supplied carbon filter or optional HEPA filter are not washable and must be replaced a...

Page 14: ...nd inlet blocked Clean out the air outlet and inlet No air out Is room temperature or humidity too low Is air strainer blocked Clean air strainer See page 13 No filter fitted Fit the filter Loud running noise The dehumidifier is tilted or unstable due to improper placement Please place the dehumidifier at stable location Is air strainer blocked Clean air strainer See page 13 Power source 230 Volts...

Page 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...