T H E   C O N T I N U O U S   P O W E R   C O M P A N Y

 

Page 7 

PHYSICAL DESCRIPTION 

his section will point out and illustrate the 
various indicators, functions and controls of 
the 

DTR(ET) Series

 UPS.  The important 

attributes of the 

DTR(ET) Series

 unit are 

numbered to assist you in locating them on your 
machine and also to fully explain its function and 
how it relates to system operation. 
Numbers on the drawing will correspond to the 
operating component’s name at the bottom with a 
brief identification.  In the next section, a complete 
explanation of all numbered items will be enhanced 
to ensure you have a full understanding of the 
operation of this system. 

Visual indicators used on the front panel are long 
lasting, very efficient, light emitting diodes (LED).  
When operating the push-button switches, always 
hold the switch in for at least two seconds to insure 
function confirmation.  This feature has been 
implemented into the system design to avoid 
inadvertent operation of any of the user-available 
functions. 
Pictured below is the front view of the model 
DT1000R(ET). Plate with items 16 through 21 can 
be repositioned to the rear panel.  Reference the 
figure on the adjacent page. 
 

13 

15 

12 

11 

14 

10 

DT1000R(ET) FRONT PANEL VIEW 

SYSTEM POWER SWITCH 

13  Alarm Silent/Test 

- Dual function switch 

INPUT AC LINE FUSE

 

14  ALARM SILENT/TEST ACKNOWLEDGE

 

3 Inverter 

- Inverter operating indicator 

 INDICATOR

 

4 AC 

In 

- Input line indicator 

15 Alarm 

- Fault indicator 

5 Load 

Level 

- Output capacity indicators 

 

 

6 Battery 

Level 

- Charge/discharge indicators 

 

 

7 Cold 

Start 

- DC start switch 

 

 

COLD START ACKNOWLEDGE INDICATOR

 

 

 

9 Load 

- Enable switch for output receptacles 

 

 

10  LOAD I ACKNOWLEDGE INDICATOR

 

 

 

11 Load 

II 

- Enable switch for output receptacles 

 

 

12  LOAD II ACKNOWLEDGE INDICATOR

 

 

 

 

 

 

 

Summary of Contents for DT1000R

Page 1: ...s proprietary confidential and not to be disclosed disseminated or used except for the purpose provided by CLARY CORPORATION P N 510 12750 REV NR Date 2 2001 CLARY CORPORATION 1960 S Walker Avenue Mon...

Page 2: ...BLE OF CONTENTS TITLE PAGE TABLE OF CONTENTS 2 INTRODUCTION 3 TECHNICAL DESCRIPTION 4 PACKAGING 6 PHYSICAL DESCRIPTION 7 INSTALLATION 10 OPERATION 11 SIGNALS AND INTERFACING 12 SPECIFICATIONS 13 CARE...

Page 3: ...nce of the UPS and batteries Be aware of the following symbols and their meaning as they appear throughout the manual This equipment generates and uses radio frequency energy and if not installed and...

Page 4: ...the supply components that keep the entire system operational Production downtime can now be virtually eliminated by knowing exactly what patterns the supply utility power maintains and by knowing ex...

Page 5: ...T H E C O N T I N U O U S P O W E R C O M P A N Y DT1000R ET UPS BATTERY BANK SIMPLIFIED SYSTEM INTERCONNECT DC IN AC IN...

Page 6: ...there is significant damage to the carton or if there is any physical damage to this unit report this to your carrier These units are encapsulated in a protective wrap that comes apart once the produc...

Page 7: ...witches always hold the switch in for at least two seconds to insure function confirmation This feature has been implemented into the system design to avoid inadvertent operation of any of the user av...

Page 8: ...communications signals 19 Signal Open collector signal contacts 20 AC In Input receptacle for all AC power 21 DC In Input receptacle for all DC power 23 SYSTEM GROUNDING STUD 24 SNMP Option Slot for s...

Page 9: ...cessful transition Load II A momentary push button switch that works identical to LOAD I except it corresponds to the LOAD II AC output receptacles at the panel Alarm Silent Test A momentary push butt...

Page 10: ...The air inlets vents and fan should not be obstructed or blocked in any way The more breathing space the system has the cooler it operates The air should remain free from excessive dust and chemical...

Page 11: ...Mode DC Start Operation Cold Start If no utility power is available at the time backup power is required the unit may be started to accomplish abbreviated tasks The limitations of the battery prevent...

Page 12: ...tdown has been accomplished The system may be configured to shutdown by applying a 5 to 12V signal across the appropriate pins Contact the factory for configuration details RS232 is a true communicati...

Page 13: ...8 0 457 Weight Lbs Kg HxWxD 30 13 5 DESIGN Standard Features Power Factor Corrected Digital Regenerative On Line Sinewave Inverter Powers Load Continuously Extended Brownout Protection Designed for No...

Page 14: ...en or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic CAUTION A battery can present a risk of electrical shock and high short circuit current The...

Page 15: ...actory In consulting the factory always have the unit model number and serial number at hand This information is located on the identification label and is essential in retrieving your unit s performa...

Page 16: ...Page 16...

Reviews: