Section 3
INSTALLATION AND OPERATIONS
3.1 INSTALLATION
The UPS system is typically rack-mounted in standard traffic cabinets. When determining how to
position the UPS system inside your cabinet, the following requirements MUST be met.
•
The installation site MUST maintain an ambient air temperature of less than 165
o
F (74
o
C).
•
The air inlets, vents and fan MUST NOT be obstructed or blocked in any way. There MUST
BE clearance around each air-inlet and vent.
•
The air should remain free from excessive dust and chemical fumes.
•
Total power requirements to be drawn from the UPS must not exceed the rated power of the
UPS.
Please note these items when designing the UPS system’s mounting hardware:
•
The front panel is designed to fit in a standard 19" rack. This panel fills a 5.25-inch slot.
3.2 PREPARATION
Installation of the SP Series Traffic UPS must be preceded by careful preparation. The following
steps are typical:
•
Ensure that the Installation Requirements will be met. (See previous section).
•
Read this manual thoroughly.
•
Assemble wiring diagrams.