6
English
Care and maintenance
Cleaning the filter
1. Press in the catch and remove the filter retainer.
2. Remove the filter from the filter retainer.
3. Use a vacuum to clean the filter.
4. Refit the filter and filter retainer.
Note:
If you rinse the filter under water, make
sure the filter is completely dry before refitting it.
Responsible disposal
This symbol indicates that this product should not be disposed of with general
household waste. This applies throughout the entire EU. In order to prevent
any harm to the environment or health hazards caused by incorrect waste
disposal, the product must be handed in for recycling so that the material can
be disposed of in a responsible manner. When recycling your product, take it to
your local collection facility or contact the place of purchase. They will ensure that
the product is disposed of in an environmentally sound manner.
Specifications
Mains adaptor
Input 100–240 V, 50 Hz
Output 24 V DC, 1.25 A
Size
450 × 277 × 225 mm
Description
Symbol
Value
Unit
Maximum fan flow rate
F
8.6
m³/min
Fan power input
P
30
W
Service value
SV
0.29
(m³/min)/W
Standby power consumption
PsB
1.2
W
Fan sound power level
LwA
55
dB(B)
Maximum air velocity
C
4.5
m/s
Measurement standard for service value: IEC 60879:1986 (corr. 1992)
Filter