Smoke Alarm

Art. no. 36-5179 

Model  D-1231

Please read the entire instruction manual before use and save it for future 
reference. We reserve the right for any errors in text or images and for making any 
necessary technical changes to this document. If you should have any questions 
concerning technical problems please contact our Customer Services. 

Placement of the smoke alarm

1.  The smoke alarm should be placed in the ceiling near bedrooms.
2.  If the bedrooms are in dierent parts of the dwelling, a smoke alarm should  

be placed in each room.

3.  In a building with several oors there should be at least  

one smoke alarm on every floor.

4.  Make sure the sound from the smoke alarm is distinctly heard.
5.  The earlier your family is warned the greater the chance of saving family 

members and salvaging property.

Interconnection

Pull cable (e.g. oval wire SKF 2 x 0.75 mm) between the smoke alarms  
that are to be connected. The smoke alarms should be connected in parallel.  
Follow the colour coding. Connect e.g. black to black and white to white.

Do not put a smoke alarm in the following places

1.  Do not place a smoke alarm in a kitchen with poor ventilation. Smoke and 

fumes from the preparation of food and baking can trigger the alarm.

2.  Do not place smoke alarm near fans or ventilation conduits. Smoke could 

drift in their direction instead of toward the smoke alarm.

3.  Do not place a smoke alarm in a garage. A car’s exhaust may trigger an alarm.

Place in ceiling  
50 cm from wall

On wall 15-20 cm  
from ceiling

Bedroom

Bedroom

Cellar

Bedroom

Bedroom

Bedroom 

 Minimum protection
 Recomended/extended protection 

4.  Do not place a smoke alarm in very damp places or a place exposed to 

broad temperature variations. A smoke alarm should not be placed in an area 
where the temperature is below 5 C° or above 40°C. 

A smoke alarm should not be painted.

Assembly

1.  Remove the bot tom plate by turning  

it slightly.

2.  Insert battery and connect the snap-on contact.
3.  Connect the optional interconnection cable  

(see further instructions).

4.  Press the test button and hold down  

a few seconds to test the alarm sound.

5.  Next check that the red light diode is blinking a 

few times per minute.

6.  Attach the bottom plate to the ceiling with the 

enclosed screws. Then screw the smoke alarm 
tightly to the bottom plate.

Alarm Pause

Silence your smoke alarm for approx. 10 min by momentarily pressing the test 
button. Ideal when non-emergency smoke (e.g. steam) causes nuisance alarms. 
Two signals are heard when the smoke alarm  
automatically resets after 10 minutes.

Test and care

1.  Test the smoke alarm at least once every month, and preferably once per 

week, e.g., when you house clean.

2.  Always test the smoke alarm after returning from holidays or after being away 

for a prolonged period. The smoke alarm can be tested with the test button.

3.  The smoke alarm sounds as long as the test button is pressed down or as 

long as there is smoke in it.

4.  Make sure the battery is correctly positioned Replace battery if the smoke 

alarm makes no noise.

5.  Below the test button is a red diode that blinks 1-2 times per minute.  

It shows that the smoke alarm is working.

6.  Wipe the surface of the smoke alarm with 

a slightly moist cloth when needed. When 
cleaning house,  the smoke alarm may be 
vacuumed slightly as you do house cleaning.

Changing batteries

A normal battery lasts for about one year. About one month before the battery is 
completely discharged, the smoke alarm will start to emit short signals at about 
one-half minute intervals. It is then time to replace the battery. Once this is done 
the detector will start working again. 
Battery: 9V standard or alkaline battery, e.g., Duracell MN 1604,  
Eveready no. 22, 1222 or 216, Gold Peak 1604 P or Ultralife U9VL-J.
Always test the smoke detector after replacing the battery.

Control lamp

Sound

Battery OK

Blinks 1-2 times/min.

Battery change  
required

Blinks 1-2 times/min.

1 short beep every minute for 
30 days.

Alarm activated

Blinks continuosly.*

Continuous alarm signal.

* Smoke detected by the ionisation chamber is indicated with green LED.  
Smoke detected by the optical chamber is indicated with red LED.

Guarantee

The smoke alarm has a 5-year guarantee calculatedfrom day of delivery.  
The guarantee covers material and manufacturing flaws and is limited to new for 
old or repairs. The guarantee is valid provided only that the instructions are followed. 
Return a defective smoke alarm to vendor or importer (address below) with  
indication of defect and battery.

Disposal

Follow local ordinances when disposing of this product. If you are unsure about 
how to dispose of this product contact your municipality.

Announcement from (Swedish)  
Radiation Safety Centre

This smoke detector contains a small amount of radioactive substance – 
americium 241.
The Swedish Radiation Safety Centre has investigated and approved  
the radiation safety of this type of smoke detector. In said test, normal use 
of the smoke detector does not expose humans to doses harmful to  
the health.

Normal use entails:

• 

Correct choice of where to place the detector.

• 

Smoke detector is used in frequented places

• 

Proper care of smoke detector, e.g., instructions for replacing battery 
and for cleaning are followed.

• 

The smoke detector must not be used by children. The smoke 
detector may be disposed of with the household rubbish.

• 

The approval number of the Swedish Radiation Safety Centre and 
the importers address are on the label on the smoke detector.

37kBq

0086-CPD-537081

EN 14604: 2005