13
EN
G
LI
S
H
Cleaning
Note:
Never immerse the entire spray gun into cleaning fluid.
After each use
1. Remove the container and pull out the suction tube.
2. Unscrew the four screws (13) under the container lid (12).
3. Detach the container lid from the motor housing (19) by pulling it downwards.
4. Remove the pump assembly from the motor housing. Take the pump apart and
clean all the components using a suitable paint thinner.
5. When reassembling the pump, make sure that the piston (11), piston spring
(10), non-return valve (8) and nozzle (6) are correctly aligned.
6. Plug the spray gun into a 230 V power point and hold it upside down. Pour a
little thin oil into the hole for the suction tube and pull the trigger. This will coat
the piston and cylinder with oil and prevent rust.
Note:
Insufficient or incorrect cleaning can lead to the piston jamming in the
cylinder. If a faint humming sound can be heard whilst spraying, release the
trigger immediately. Otherwise the motor can overheat and become damaged.
1
11
10
13
12
8
6
Summary of Contents for FL-999