• Replace the battery immediately if the battery warning symbols appears on the dis-
play. A weak battery can cause incorrect results and thereby pose a safety hazard.
• Neither the meter nor its accessories may be dismantled or modified in any way.
• Remove the battery from the meter if it is not to be used for an extended period.
• Turn the meter off after use.
• If the meter is placed close to a strong magnetic field, it might cause incorrect
readings which can be corrected by removing the cause of the interference.
Functions
1. LCD display
2. Press the required number of
times to select the required
mode: Resistance, diode test
or continuity (position Ω only).
3. [ REL
r
] Relative
measurement, press once
to use the current reading
as a reference and subtract
the previous reading from
the current reading*.
Press once again to return to
normal measurement mode.
This function cannot be used
for frequency measurement
or relative pulse length
(Duty Cycle). When relative
measurement is selected,
the symbol
r
will be shown on
the display.
4. Multifunction selector with
five modes.
5. [ Hz/% ] Frequency measurement
(Hz) or Duty Cycle value (%)
6. [ HOLD ] Press once to store
the current reading, press once
to return to normal measu-
rement mode. When hold is
selected, the symbol “H” will be
shown on the display.
7. Test leads: Black (-, negative)
Red (+, positive)
* Example: If the stored value is 20.3 V and the present value is 22.0 V, the reading
would be 1.7 V if the REL function is activated.