AC 8000
AUTOMATIC AIR CONDITIONING STATION R1234yf
AC 8134
AUTOMATIC AIR CONDITIONING STATION R134a
40
SETTINGS
Settings of the unit’s operating parameters
Select the settings functions menu
from the home page. Press
ENTER
to select from the diff erent setting
options.
«Date/Time» to set the current
date and time, press
ENTER
,
change the values with the
UP/
DOWN
buttons, press
ENTER
to
move to the next setting,
ENTER
to confi rm.
Set the language to be used by the
unit using the
UP/DOWN
buttons
and press
ENTER
to confi rm the
setting.
Set the LCD contrast/brightness
values and press
ENTER
to
confi rm.
Set the length of the charging
pipes (default setting is 3000 cm).
NOTE: If the hose length is set to
«0», the unit will recover any gas
residue left in the hoses at the end
of the A/C system cycle instead of
recovering it back into the unit.
Adjust the oil viscosity value when
the unit does not have an oil scale.
It can be noticed that the amount
of oil charged is incorrect.
Increasing the value leads to
longer valve opening times and
higher oil quantities.
Settings
Date/time
Language
LCD settings
Length of pipe
Oil viscosity