RECOMMENDATIONS BEFORE OPERATION

The heater may only be used in open or at least well ventilated rooms.

IMPORTANT!

 Be careful not to block the intake grille of the heater. Any work on the heater must be carried 

out when the heater is cold and the power plug is disconnected. The socket must be

The socket outlet must have an effective grounding system. Never bring flammable or explosive materials 

near the unit. The room where the appliance is used must be adequately ventilated and free of and the 

absence of any residue of dust, gas or vapors that are flammable or toxic at high temperatures. Never fill up 

with fuel while the appliance is in operation; any possible loss of fuel on the floor must be fuel on the floor 

must be carefully wiped off. Do not allow the fan suction to attract paper, cloth, plastic, powders or any 

other material that could clog or damage the unit. Never operate the generator without fuel: despite the 

intervention of the control box, which stops the unit, running without fuel may cause the fuel pump to seize. 

Use only the type of fuel indicated on the machine’s technical data plate.

N.B

. Do not add petrol or other solvents to the fuel; in the case of use at particularly low temperatures, use 

fuel with additives that are readily available on the market.

Electrical connections :

Warning

Before starting up the machine, check that the connection voltage corresponds to that indicated on the 

data sheet on board the machine. 

 

-  

The connection must be made in accordance with the standards and must be properly 

grounded.  

 

-  Have a qualified electrician install a high-sensitivity differential circuit breaker, intervention at 30 

mA or less. 

 

-  If necessary, it is possible to use extension cables with a cross-section of 1.5 mm2 for lengths up to 

10 m. and 2.5 mm2 for lengths between 10 and 50 m.

In case of replacement of the original power supply cable, use a cable with an adequate cross-section and a 

grounding conductor; the cable must have a continuous insulating coating suitable for use outdoors and in 

closed areas. The cable must have a continuous insulating coating suitable for use outdoors and in enclosed 

areas. A fume exhaust in accordance with the standards must be provided.

SWITCHING ON / OFF

Start-up (without room thermostat)

• Fill the fuel tank with fuel.

• Insert the plug into the socket (the red light comes on).

• Turn the ON/OFF switch to the 

ON

 position (the green light comes on and the fan starts).

• The automatic ignition cycle is started by the control box.

After a few seconds of automatic monitoring, the generator remains regularly in operation.

• If, due to some small irregularities, the unit stops and the 

RESET

 light is on, the 

RESET

 button must be 

pressed to restart the ignition cycle.

Start-up (without room thermostat)

• The unit is already adapted to be connected to a room thermostat (optional).

• If necessary, the connection should be made using the socket provided for this purpose on the

electrical panel.

• After setting the room thermostat, turn the switch to the AUT position. To switch off the appliance, 

use either the main switch or the room thermostat. In both cases, a correct cooling cycle of the 

generator is guaranteed.

During normal operation of the machine, the 

RESET

 button flashes. In case of a malfunction, the 

button remains lit for 10 seconds. Determine and solve the cause of the

If necessary, determine and solve the cause of the problem and reset the machine by pressing the 

RESET

 button.

Summary of Contents for CH 0022

Page 1: ...CH 0022 CHAUFFAGE FIOUL DIRECT 20kw DIRECT DIESEL OIL HEATER 20kw CH 0023 CHAUFFAGE FIOUL DIRECT 30kw DIRECT DIESEL OIL HEATER 30kw CH 0024 CHAUFFAGE FIOUL DIRECT 40kw DIRECT DIESEL OIL HEATER 40kw CH...

Page 2: ...sur notre site clas com Si vous avez chang d avis concernant votre achat veuillez retourner ce produit avant d essayer de l installer Before returning this product for any reason installation problem...

Page 3: ...14 197 16 5 500 1 39 Diesel Kerosene 20 100 230 50 79x27x50 21 CH 0023 17 200 20 500 1 66 20 100 230 50 79x27x50 24 CH 0024 25 800 30 1 750 2 53 35 150 230 50 125x55x65 44 CH 0025 34 400 40 1 750 3 3...

Page 4: ...4 CH 0022 CH 0023 CH 0024 CH 0025 CH 0026 SCHEMAS ELECTRIQUES P Pompe S Appareillage EV Electrosoupape F Fusible C Interrupteur M Moteur SR Sonde TL Thermostat TA Thermostat ambiant...

Page 5: ...CHAUFFAGE FIOUL DIRECT 16 5kw 20kw 30kw 40kw 50kw 5 VUE CLAT E T te de combustion Porte buse Capsule de t te lectrodes...

Page 6: ...6 CH 0022 CH 0023 CH 0024 CH 0025 CH 0026 Porte buse...

Page 7: ...CHAUFFAGE FIOUL DIRECT 16 5kw 20kw 30kw 40kw 50kw 7 T te de combustion...

Page 8: ...ces salles les g n rateurs directs ne doivent tre utilis s que pour s cher les salles si l on garantit la quantit d air n cessaire pour la combustion vous obtenez la quantit d air n cessaire quand la...

Page 9: ...re installer par un lectricien qualifi un disjoncteur diff rentiel haute sensibilit intervention 30 mA ou inf rieure En cas de n cessit il est possible d utiliser des rallonges du c ble d alimentation...

Page 10: ...la partie int rieure de la t te de combustion s enl ve il reste seulement le corps cylindrique et l embout conique accessible pour le nettoyage N B Pendant le remontage de la t te apr s avoir effectu...

Page 11: ...ion est d fectueuse remplacer S assurer si une tincelle se produit entre les lectrodes Dans le cas contraire v rifier la position et le bon tat des lectrodes et des c bles haute tension V rifier si le...

Page 12: ...6 5 500 1 39 Diesel Kerosene 20 100 230 50 79x27x50 21 CH 0023 17 200 20 500 1 66 20 100 230 50 79x27x50 24 CH 0024 25 800 30 1 750 2 53 35 150 230 50 125x55x65 44 CH 0025 34 400 40 1 750 3 37 35 150...

Page 13: ...13 DIRECT DIESEL OIL HEATER 16 5kw 20kw 30kw 40kw 50kw ELECTRICAL DIAGRAMS P Pump S Equipment EV Electrovalve F Fuse C Switch M Motor SR Probe TL Thermostat TA Ambient thermostat...

Page 14: ...14 CH 0022 CH 0023 CH 0024 CH 0025 CH 0026 EXPLODED VIEW Combustion head Porte buse nozzle holder capsule de t te head cap electrodes...

Page 15: ...15 DIRECT DIESEL OIL HEATER 16 5kw 20kw 30kw 40kw 50kw Nozzle holder...

Page 16: ...16 CH 0022 CH 0023 CH 0024 CH 0025 CH 0026 Combustion head...

Page 17: ...the entrance must prohibit the permanent presence of people in these rooms direct generators should only be used to dry rooms if the necessary amount of air for combustion is guaranteed you get the n...

Page 18: ...vity differential circuit breaker intervention at 30 mA or less If necessary it is possible to use extension cables with a cross section of 1 5 mm2 for lengths up to 10 m and 2 5 mm2 for lengths betwe...

Page 19: ...letely removed Unscrew the 2 screws the entire inner part of the combustion head is removed leaving only the cylindrical body and the conical end accessible for cleaning N B When reassembling the head...

Page 20: ...ustion control box is defective replace it Check whether there is a spark between the electrodes If not check position and If not check the position and condition of the electrodes and high voltage ca...

Page 21: ...21...