The machine emits different acoustic signals based on its status. The acoustic signals are listed in table
The acoustic signal is also heard for about two seconds at machine start-up allowing the operator to check the operation of the
alarm (buzzer).
The information in the table above is general and can be used as a rough guide. The responsibility for the use of each type of
extinguisher must be obtained from the manufacturer.
ACOUSTIC SIGNALS
FIRE PREVENTION MEANS TO USE
Signals
Meaning
Notes
Very brief beep
Manual entry of wheel geometric data.
Short beep
Selecting a program or a function.
Long beep
Acquisition.
• Acquisition of a value
• Acquisition of the wheel dimensions in the STD,
ALU1, ALU2, ALU3, ALU4, ALU5 Program Types.
Long beep + 1 Short beep
Acquisition of internal plane in ALS1 or ALS2
Program Types.
Long beep + 2 Short beep
Acquisition of external plane in ALS1 or ALS2
Program Types.
Double beep
Warning.
A particular condition has occurred that requires
the operator’s attention.
Triple beep
Function not available or Error.
The requested function is not available or an error
condition has occurred.
Short Beep + Long beep
Storing one or more values in the permanent memo-
ry (eeprom) of the circuit board.
One or more values have been stored in the perma-
nent memory of the circuit board (for example, at
completion of calibration phases).
Intermittent beep
Adjustment.
Signal used in some service programs to simplify
the adjustment of sensors.
YES*: Can be used in the absence of more appropriate means or for small fires.
Dry materials
Flammable liquids
Electrical equipment
Hydraulic
YES
NO
NO
Foam
YES
YES
NO
Powder
YES*
YES
YES
CO2
YES*
YES
YES