background image

clas.com

THERMOMETRE INFRAROUGE -38°/520°

OE 5036

INFRARED THERMOMETER -38°/520°

Summary of Contents for OE 5036

Page 1: ...clas com THERMOMETRE INFRAROUGE 38 520 OE 5036 INFRARED THERMOMETER 38 520...

Page 2: ...ur notre site clas com Si vous avez chang d avis concernant votre achat veuillez retourner ce produit avant d essayer de l installer Before returning this product for any reason installation problem i...

Page 3: ...laser vers les yeux d autrui et faire attention ne pas atteindre les yeux d autrui en dirigeant le faisceau laser sur une surface r fl chissante 4 Garder hors de port e des enfants 5 Ne pas utiliser l...

Page 4: ...esur e et la temp rature de r f rence est comprise dans les limites du seuil d fini LOW Appara t lorsque la diff rence entre la temp rature mesur e et la temp rature de r f rence est inf rieure au seu...

Page 5: ...couvercle vers le bas Remplacez les piles usag es par des piles neuves en faisant attention la polarit Remettez le couvercle 1 Pointez le thermom tre vers la cible Appuyez sur la g chette et maintenez...

Page 6: ...que la diff rence entre la temp rature mesur e et la temp rature de r f rence est inf rieure au seuil d fini la lumi re de r tro clairage est bleue et le symbole LOW appara t en haut et droite de l cr...

Page 7: ...sser les mesures Plus le thermom tre est loign de la cible plus le diam tre de la cible est large Ce rapport entre la distance de la cible et le diam tre du champs de mesure s exprime par D S Lorsque...

Page 8: ...ondensation Conditions de stockage 20 C 60 C 85 humidit relative Dimensions 160 x 118 x 40 mm Poids 155g environ piles incluses 1 Des modifications peuvent tre apport es ce mode d emploi tout moment 2...

Page 9: ...Use extreme caution when operating the laser 3 Do not point the laser beam toward anyone s eye or allow the laser beam to strike the eye from a reflective surface 4 Keep the thermometer out of reach...

Page 10: ...ce between the presently scanned temperature and the reference temperature does not exceed the threshold LOW Appears when the presently scanned temperature is lower than the reference temperature by m...

Page 11: ...t the polarity connections are correct Reinstall the battery caver 1 Hold the thermometer and point it toward the target to be measured Pull and hold the trigger for at least 1 second to start measuri...

Page 12: ...nd slow beeps about one beep per second if the presently scanned tempe rature is lower than the reference temperature by more than the threshold The backlight will be red and the symbol HIGH will appe...

Page 13: ...her the thermometer is from the target the larger the target area will be This relationship between distance and target size is normally expressed as the distance to spot or D S ratio Al a distance of...

Page 14: ...condensing Storage Temperature 20 C 60 C 85 RH Dimensions 160 X 118 X 40mm Weight About 155g including battery 1 This Instruction Sheet is subject to change without notice 2 CLAS will not take the oth...

Page 15: ......

Page 16: ...revendeur En cas de probl me veuillez contacter le technicien de votre distributeur agr CLAS Equipements 83 chemin de la CROUZA 73800 CHIGNIN FRANCE T l 33 0 4 79 72 62 22 Fax 33 0 4 79 72 52 86 THERM...

Reviews: