background image

 

 

6

-       -  

BRIDGED OPERATION: 

 

 The six (6) channels of the CAV-75 are divided into three (3) groups. These groups can be 

operated and configured independently _ Channel-1 with Channel-2, Channel-3 with Channel-4, and 

Channel-5 with Channel-6. When in bridged mode, the inputs of CH-1, CH-3 and CH-5 are used 

respectively (as marked above the jacks). The unused inputs of CH-2, CH-4 and CH-6 are 

automatically disconnected when configured in bridged mode.  The following steps should be 

performed to switch between NORMAL and BRIDGED modes. 

 

1) Turn OFF the unit and remove all connections, including the AC linecord. 

 

2) Remove top cover with the Allen key supplied. 

 

3) Locate the input board(s) of channels to be switched. (see fig.1 page 7)   

 

4) Locate and set jumpers to the desired operation mode. (see fig.2a, 2b page 8) 

 

5) Replace and secure the top cover. 

 

6) Reconnect all cables. Make sure the input and output connections are according to the 

 

operating mode. (see fig.3a&3b page 9) 

Please read through the previous normal section for general notes on securing good connections, and 

safety tips. 

CAUTION:

 Please remember that the negative output connection of a bridged amplifier is NOT a 

ground.  Do not use a "common ground" or switchbox set-up.  Do not use with electronic crossovers 

which have a common ground.  

 

REMOTE CONTROL:

 (optional) 

 

With a simple connection from the receiver box to the remote jack at the back of the 

amplifier, (see Fig.2 page 8) the power amplifier can be turned ON/OFF from a distance (or from 

another room). 

 

 

Summary of Contents for CAV-75

Page 1: ...CLASS AUDIO CAV 75 MULTI CHANNEL POWER AMPLIFIER CAV 75 OWNER S MANUAL...

Page 2: ...preamps are the same The same circuit is tailored to different power levels etc Differences between less expensive models and more expensive models are parts quality and compliment power supply extrav...

Page 3: ...3 CAV 75 OWNER S MANUAL TABLE OF CONTENTS UNPACKING SET UP 4 GENERAL CONNECTIONS AND OPERATIONS 5 CONNECTIONS AND DIAGRAMS 7 PROTECTION CIRCUIT 10 SPECIFICATIONS 12...

Page 4: ...LASS REFERENCE A C LINECORD Consult your dealer regarding this accessory The power transformer in the CAV 75 is located at the front left of the unit Ideally a few feet should separate this area from...

Page 5: ...THE WALL OUTLETS THIS WILL REDUCE THE POTENTIAL SHOCK HAZARD SEE ALSO THE WARRANTY SECTION OF THIS OWNER S MANUAL NORMAL OPERATION Input and output connectors for each channel are clearly grouped and...

Page 6: ...cate the input board s of channels to be switched see fig 1 page 7 4 Locate and set jumpers to the desired operation mode see fig 2a 2b page 8 5 Replace and secure the top cover 6 Reconnect all cables...

Page 7: ...7...

Page 8: ...8...

Page 9: ...9...

Page 10: ...sure that the situation that has triggered the protection circuit has been corrected Failing to correct the situation prior to re starting the unit can result in damaging vital components in the unit...

Page 11: ...11 CLASS AUDIO 5070 Francois Cusson Lachine Quebec Canada H8T 1B3 Telephone 514 636 63 85 Fax 514 636 14 28...

Page 12: ...shes CAV 75 SPECIFICATIONS Frequency Response 20 Hz to 20 KHz 0 1 dB Sensitivity 0 85 Volt in for rated output Input Impedance 75 Kohms Output Impedance 0 15 Ohm S N Ratio More than 135 dB THD N 0 004...

Page 13: ...the European Community CE mark This means that your Class product has been subjected to the most rigorous manufacturing and safety tests in the world and have proven to meet or exceed all European Co...