30
For MWOHC24S model:
T1-Ts
4¡ãC(39.2¡ãF)
3¡ãC(37.4¡ãF)
1.5¡ãC(34.7¡ãF)
1.0¡ãC(33.8¡ãF)
T1-Ts-
¦
T
¤
5.0¡C
ã (41¡ F
ã)
4.5¡C
ã (40.1¡F
ã)
3.5¡C
ã (38.3¡ F
ã)
3.0¡ C
ã (37.4¡F
ã)
2.5¡C
ã (36.5¡ F
ã)
2.0¡C
ã (35.6¡ F
ã)
1.5¡C
ã (34.7¡ F
ã)
1.0¡C
ã (33.8¡ F
ã)
0.5¡C
ã (32.9¡ F
ã)
8.4.3 Heating Mode
8.4.3.1 Compressor running rules
The maximum operation frequency of the
compressor after starting submits to the
following rule.
T4
34¡ãC(93.2¡ãF)
33¡ãC(91.4¡ãF)
28¡ãC(82.4¡ãF)
27¡ãC(80.6¡ãF)
25¡ãC(77.0¡ãF)
24¡ãC(75.2¡ãF)
22¡ãC(71.6¡ãF)
21¡ãC(69.8¡ãF)
19¡ãC(66.2¡ãF)
18¡ãC(64.4¡ãF)
17¡ãC(62.6¡ãF)
16¡ãC(60.8¡ãF)
15¡ãC(59.0¡ãF)
14¡ãC(57.2¡ãF)
12¡ãC(53.6¡ãF)
11¡ãC(51.8¡ãF)
6.0¡ãC(42.8¡ãF)
5.0¡ãC(41.0¡ãF)
While the zones of A,B,C... are corresponding
to different compressor running frequency.
ΔT=0°C(32°F) as default.
Note:
When T1-Ts keeps in the same temp. zone for
3 minutes, the compressor will run as the below
rules:
A~E: Increase the frequency to the higher level
until to F10.
F: Keep the current frequency.
G: Decrease the frequency to the lower level
until to F1.
H: Run at F1 for 1h.(if T1-Ts-ΔT >6°C(42.8°F),
the compressor will stop)
Meanwhile, the compressor running frequency
is limited by the current.
I3HEAT
Fmax: The maximum operation frequency of
compressor.
F1~F8: The detailed value of the compressor
operation frequency.
If users switch on AC by remote controller, the
compressor will run at the Fmax frequency for 7
minutes according to outdoor ambient temp.
During the 7 minutes, the frequency limitation is
active.
7 minutes later, the compressor running
frequency will be controlled as below:
I2HEAT
I1HEAT
I3HEAT, I2HEAT,I1HEAT mean different
running current value.
Off: Compressor stops.
Decrease: Decrease the running frequency to
the lower level.
Hold: Keep the current frequency.
High
Medium
Low
Off
Fmax=F2
Fmax=F3
Fmax=F4
Fmax=F5
Fmax=F6
Fmax=F7
Fmax=F8
Fmax=F9
Fmax=F10
H
G
F
E
D
C
B
A
Off
Decrease
Hold
Resume
Summary of Contents for MROHC09AS
Page 14: ...12 5 Wiring Diagram 5 1 Indoor Unit MWOHC09S MWOHC12S MWOHC18S ...
Page 15: ...13 MWOHC24S ...
Page 16: ...14 5 2 Outdoor Unit MROHC09AS MROHC12AS ...
Page 17: ...15 MROHC18AS ...
Page 18: ...16 MROHC24AS MROHC09AS MROHC12AS ...
Page 19: ...17 MROHC18AS ...
Page 29: ...27 T2 7 C 44 6 F the compressor frequency will not be limited ...
Page 53: ...51 Take the 9k model as example P V P U ...
Page 54: ...52 N U P W ...
Page 55: ...53 N W N V ...