background image

11

ALPHA WASH 1500 LT

Continue  

SETTING
Used  to  save  3  different  settings  of  the  items  in  the  options  menu  and
relative submenus.
1) Press

F

- “Default preset” appears on the display.

2) Use  the  UP 

B

and  DOWN 

C

keys  to  select  one  of  the  following

configurations:
- Default preset (*)
- User preset 1
- User preset 2
- User Preset 3

3) Press

F

- “Load preset X” appears on the display.

4) Use the UP 

B

and DOWN 

C

keys to select:

- Load preset X to recall a previously stored configuration.
- Save to preset X to store the current configuration.
a confirmation message (Are you sure?) appears on the display.

5)  Select YES to confirm the selection or NO to keep the current setting

and return to the next higher level.

(*) DEFAULT PRESET 
Used for restoring default values on all options menu items and relevant
submenus.
1) Press

F

,  a  confirmation  message  (Are  you  sure?)  appears  on  the

display .

2) Select YES to confirm the selction or NO to keep current setting.
OPTION

DEFAULT

Lamp DMX

On

Invert Pan

Off

Invert Tilt

Off

Swap Pan-Tilt

Off

Encoder Pan-Tilt

On

Colour mixing 

CMY

Fixed Wheel Shortcut 

On

Shutter on error    

Off

Dimmer on Shutter     

Off

Display       

On

SYSTEM ERRORS
Shows a list of warnings and messages relevant to errors occurred since
the fixtures switching-on.
1) Pressing

F

you are allowed to reset the SYSTEM ERRORS list.

A  confirmation  message  (Are  you  sure  you  want  to  clear  error  list  ?)
appears on the display.

2) Select YES to reset the list or NO to go back.

FIXTURE HOURS
Used for displaying projector operating hours (total and partial).
1) Press

F

- Hours total and partial appears on the display.

Total counter
Counts the number of projector working life hours (from manufacture to date). 
Partial counter
Counts the number of partial projector working life hours since the last
reset to date.

2) Press

F

to  reset  partial  projector  working  hours  a  confirmation

message (Are you sure?) appears on the display.

3) Select YES to reset partial projectors counter or NO to keep the current

setting and return to the top menu level.

Information

INFORMATION MENU

Reset To

Dafault

Go Back

Setting

Default

Preset

Load 

Preset 1

Save To
Preset 1

User

Preset 1

Load 

Preset 2

Save To
Preset 2

User

Preset 2

Load 

Preset 3

Save To
Preset 3

User

Preset 3

System 

Errors

Fixture 

Hours

Total

XXX

Partial XXX

Reset...                                   

Summary of Contents for ALPHA WASH 1500 LT

Page 1: ...manual to ensure the fitting is installed used and serviced correctly and safely CLAY PAKY S p A disclaims all liability for damage to the fitting or to other property or persons deriving from install...

Page 2: ...must be carried out by a qualified electrical installer Check that the mains frequency and voltage correspond to those for which the projector is designed as given on the electrical data label This l...

Page 3: ...WASH 1500 LT UNPACKING AND PREPARATION Lamp 1500W fitted into projector 099398 2 x 183102 802 1 90 9 0 9 0 9 0 LOCKED UNLOCKED PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Rel...

Page 4: ...alled on the floor resting on special rubber feet on a truss or on the ceiling or wall WARNING with the exception of when the projector is positioned on the floor the safety cable must be fitted Cod 1...

Page 5: ...est status It should be noted than when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled CONTROL PANEL 1 2 Dmx Address Warning Mess...

Page 6: ...ll over again Setting the projector starting address On each projector the starting address must be set for the control signal addresses from 1 to 512 The address can also be set with the projector sw...

Page 7: ...ptions Informations Informations Menu To read the counters software version and other information Manual Control Manual control Menu To trigger the test and manual control functions Test Test Menu To...

Page 8: ...Pan Tilt Color Mixing Fixed Wheel Shortcut Setting Default Preset User Preset 1 User Preset 2 User Preset 3 Shutter Shutter On Error Dimmer On Shutter Lamp Strikes System Version Board Diagnost Dmx M...

Page 9: ...EFT Dto keep current settings NOTE On grey the default options LAMP DMX Used for enabling lamp remote control channel 1 Press F the current settings appear on the display On or Off 2 Use the UP B and...

Page 10: ...N C keys to enable On or disable Off color change optimization 3 Press Fto confirm the selection or LEFT Dto keep current settings SHUTTER Shutter on error Used for automatically closing the stop stro...

Page 11: ...ing CMY Fixed Wheel Shortcut On Shutter on error Off Dimmer on Shutter Off Display On SYSTEM ERRORS Shows a list of warnings and messages relevant to errors occurred since the fixtures switching on 1...

Page 12: ...on message Are you sure appears on the display 3 Select YES to reset partial counter or NO to keep the current setting and return to the top menu level SISTEM VERSION Used for displaying the software...

Page 13: ...vel CHANNEL Used for setting channel levels from the projector control panel 1 Press F the first channel appears on the display 2 Use the UP Band DOWN Ckeys to select the required channel 3 Press F an...

Page 14: ...ears on the display 2 Using the UP B and DOWN C keys select the effect you wish to regulate 3 Press Fand use the RIGHT E UP Band DOWN Cbuttons to make the adjustment by setting a value between 0 and 2...

Page 15: ...g and releasing Pan and Tilt movements Refer to the instructions in the UNPACKING AND PREPARATION section Opening the head covers Fig 10 Closing the head covers Fig 11 1 4 Turn 1 1 4 Turn 1 3 2 1 2 4...

Page 16: ...fitting WARNING do not touch the lamp s envelope with bare hands Should this happen clean the bulb with a cloth soaked in alcohol and dry it with a clean dry cloth Lamp regulation Fig 14 To centre the...

Page 17: ...17 ALPHA WASH 1500 LT Fan support plate opening and closing Lower side Fig 15 3 2 1 Lower Side 4 15 Fan support plate opening and closing Upper side Fig 16 Upper Side 1 2 16 Continue...

Page 18: ...etc Use a soft cloth dampened with any detergent liquid for cleaning glass to remove the dirt from the reflectors from the lenses and filters It is recommended that the projector undergoes an annual...

Page 19: ...19 ALPHA WASH 1500 LT Extraction of the effect modules Preliminary operations Fig 18 2 3 1 4 Cut Out Upper Side Lower Side 18 Continue...

Page 20: ...4 13 Upper Side 15 Upper Side Extraction of the effect modules Fig 19 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect module...

Page 21: ...t modules Fig 20 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 19 and 20 in...

Page 22: ...mm 0 47 No protection against the entry of liquids CE Marking In conformity with the European Union Low Voltage Directive 2006 95 CE and Electromagnetic compa tibility Directive 2004 108 CE Safety Dev...

Page 23: ...SHAPER MOVEMENT ZOOM PAN PAN FINE TILT TILT FINE FUNCTION RESET LAMP CONTROL with Option Lamp DMX ON 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 CYAN MAGENTA YELLOW C T O COLOUR WHEEL STO...

Page 24: ...f power 1 second after all the 3 channels stay at 0 level The lamp goes back to full power when the channels level is put higher than 0 STOP STROBE channel 6 IMPORTANT The lamp dim to half power 1 sec...

Page 25: ...ER INSERTION channel 9 BEAM SHAPER MOVEMENT channel 11 ZOOM channel 12 PAN FINE channel 14 Operation with option InvertPanGOff Tilt conventionally represented at 14 and option Invert TiltGOff BIT 255...

Page 26: ...g 5 seconds in complete reset levels COMPLETE RESET PAN TILT RESET PAN TILT RESET EFFECTS RESET EFFECTS RESET UNUSED RANGE Pan Tilt reset is activated passing throug the unused range and staying 5 sec...

Page 27: ...39 126 127 40 128 BIT Seconds 129 130 41 131 132 42 133 134 135 43 136 137 44 138 139 140 45 141 142 46 143 144 145 47 146 147 48 148 149 150 49 151 152 153 50 154 155 51 156 157 158 52 159 160 53 16...

Page 28: ...CLAY PAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 Fax 39 035 301876 www claypaky it Rev 0 01 10 Cod 099398 EN www gfstudio com...

Reviews: