• Installation
Make sure all the parts for fixing the projector are in a good state of repair.
Make sure the point of anchorage is stable before positioning the projector. 
The safety rope, properly hooked onto the fitting and secured to the framework, must
be installed so that, if the primary support system fails, the fitting falls as little as
possible. If the safety rope gets used, it needs to be replaced with a genuine spare.

SAFETY INFORMATION

1

INSTRUCTIONS MANUAL

Carefully read this instructions manual in its entirety and keep it safe for future
reference.

It is essential to know the information and comply with the instructions given
in this manual in order to ensure the fitting is installed, used and serviced
correctly and safely.

CLAY PAKY S.p.A. disclaims all liability for damage to the fitting or to other
property or persons deriving from installation, use and maintenance that have
not been carried out in conformity with this instructions manual, which must
always accompany the fitting. 

CLAY PAKY S.p.A. reserves the right to modify the characteristics stated in
this instructions manual at any time and without prior notice.

Congratulations on choosing a Clay Paky product! We thank you for your
custom. Please note that this product, as all the others in the rich Clay Paky
range, has been designed and made with total quality to ensure excellent
performance and best meet your expectations and requirements.

• Maximum ambient temperature

For the fitting to operate well and reliably, the ambient temperature should not
exceed 35°C (95°F).

• IP20 protection rating

The fitting is protected against penetration by solid bodies of over 12mm (0.5”) in
diameter (first digit 2), but not against dripping water, rain, splashes or jets of water
(second digit 0).

• Protection against electrical shock

This fitting is classified in accordance with the type of protection against electrical
shock, in Class I. It must therefore be connected to a power supply system with
efficient earthing.
It is however recommended to protect the supply lines of the projectors from indirect
contact and/or shorting to earth by using appropriately sized residual current
devices.

• Connecting to the supply mains

Connection to the electricity mains must be carried out by a qualified electrical
installer.
Check that the mains frequency and voltage correspond to the frequency and
voltage stated on the electrical data label for which the projector is designed.
This label also gives the input power. Refer to this to evaluate the maximum number
of fittings to connect to the electricity supply in order to avoid overloading. 

• Maintenance

Before starting any maintenance work or cleaning the projector, cut off power from
the mains supply.
After switching off, do not remove any parts of the fitting for 10 minutes. 
After this time the likelihood of the lamp exploding is virtually null. If it is necessary to
replace the lamp, wait for another 15 minutes to avoid getting burnt.
The fitting is designed to hold in any splinters produced by a lamp exploding. 
The lenses must be fitted and, if visibly damaged, they have to be replaced with
genuine spares.

• Temperature of the external surface

The maximum temperature that can be reached on the external surface of the fitting,
in a thermally steady state, is 90°C (194°F).

• Lamp

The projector mounts a high-pressure lamp that needs an external igniter.
This igniter is fitted onto the projector.

- Carefully read the "operating instructions" provided by the lamp manufacturer.

- Immediately replace the lamp if damaged or deformed by heat.

It is permissible to mount the fitting on normally flammable surfaces.

The products referred to in this manual conform to the
European Community Directives to which they are subject:

• Low Voltage 73/23 

• Electromagnetic Compatibility 89/336

HMI 1200

• Minimum distance from target objects

The projector must be positioned in such a way
that objects struck by the beam are separated
from the lens at least by the distance indicated
on the lamp change label against the symbol
shown alongside.

• Minimum distance of flammable materials

The projector must be positioned so that any flammable materials are at least 
0,1 meter (4”) for HMI 1200 and 0,07 meter (3”) for HMI 575 from every point on the
surface of the fitting.

(8’ 2’’)

2.5 m

HMI 575

(5’ 11’’)

1.8 m

Summary of Contents for HMI 575

Page 1: ... protect the supply lines of the projectors from indirect contact and or shorting to earth by using appropriately sized residual current devices Connecting to the supply mains Connection to the electricity mains must be carried out by a qualified electrical installer Check that the mains frequency and voltage correspond to the frequency and voltage stated on the electrical data label for which the...

Page 2: ...03 002 4 2 eyebolts M8x20mm code 167004 001 5 2 nuts M8 code 020106 006 6 2 knobs code 020502 7 2 plane washers ø10 5mm code 020210 004 8 1 bracket code 101011 001 9 4 bracket bushings code 101014 001 10 4 countersunk washers code 080606 001 11 4 countersunk head screws M8x20mm code 020005 001 12 1 Allen wrench 5 mm code 050001 13 4 handles code 082017 001 14 only for TV version 8 screws TCEI M8x2...

Page 3: ...and control unit and between different projectors must be made with a cable conforming to the EIA RS 485 specifications bipolar braided shielded 120Ω characteristic impedance 22 24 AWG low capacity IMPORTANT Do not use microphone cable or any other cable whose specifications are different to the ones stated above The terminations need to be made with male female connectors type XLR with 5 pins If ...

Page 4: ...nnels 37 42 Projector 9 Channels 49 54 Projector 10 Channels 55 60 Projector 8 Channels 43 48 DIGITAL START ADDRESS SELECT OPTION SELECT DIGITAL INPUT LEDS 1 4 8 1 2 4 8 16 128 32 64 TEST 256 ON 1 2 4 3 6 5 7 8 10 9 DIGITAL INPUT 1 2 4 3 6 5 The above information can also be displayed by carrying out at least one of the following operations Setting all the DIL Dual In Line switches of the addresse...

Page 5: ...eeds to be positioned with the protrusion 31 visible on the bulb outside the optical axis of the projector For this purpose it is recommended to turn the protrusion towards the top cover 18 27 24 32 25 34 34 33 Replacing colour filters Find the filter to be replaced grip it between your fingers and push it towards the movable point of anchorage 33 until the filter comes out of the fixed points of ...

Page 6: ...0µF standard HMI 1200 Version 3000VA at 220V 50Hz HMI 575 Version 1500 VA at 220V 50Hz Motors 9 stepper motors operating with micro steps totally microprocessor controlled Optical unit Base in die cast aluminium Twin lens condenser Spherical reflector with a high luminous efficiency Lens unit Standard 1 2 5 250 mm Optional 1 3 3 300 mm Optional 1 1 6 160 mm to be fitted internally of projector HMI...

Page 7: ...12 GOLDEN SCAN 3 HMI 575 HMI 1200 HMI 1200 TV ACCESSORI OPZIONALI OPTIONAL ACCESSORIES ACCESSOIRES OPTIONNELS OPTIONALE ZUBEHÖRTEILE ACCESORIOS OPCIONALES C21061 C21029 C21030 ...

Reviews: