Switching on the projector - Fig. 8

Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:

                                         Model                                      Firmware                              xxx (Fixture ID)                      System errors

                                                         SCENIUS                                Version X.X.X                      Dmx Address xxx                  E: .........................

                                                                                                          Date - Hour                                                                         W: .........................

On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 128 bit - Tilt 128 bit). The control
panel (Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two
conditions: rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the Fixture ID address
(if set). 

During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.
It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the

F

key will be cancelled.

CONTROL PANEL

1

2

Dmx Address

Warning Message

Fixture ID

 

 

8

Connecting to the control signal line (DMX) - Fig. 7
Use  a  cable  conforming  to  specifications  EIA  RS-485:  2-pole  twisted,  shielded,  120Ohm  characteristic  impedance,  22-24  AWG,  low  capacity.  Do  not  use
microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 5-pin male/female
connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.
IMPORTANT: The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the
shield braid and to pin 1 of the connectors.

Connecting to the mains supply - Fig. 6

 

 

 

 

 

 

 

 

SIGNAL

SCREEN

DMX 512

5 PIN

1

2

3

4

5

SIGNAL

Mains

6

7

Summary of Contents for C61500

Page 1: ... the rich Claypaky range has been designed and made with total quality to ensure excellent performance and best meet your expectations and requirements INDEX ENGLISH Page Contents 2 Safety information 3 Unpacking and preparation 4 Installation and start up 5 Control panel 7 Maintenance 18 Optional accessories 19 Technical information 20 Cause and solution of problems ...

Page 2: ...er folgendem Link auffindbar http www claypaky it en download Ref FIS00L Safety Information Scenius INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace http www claypaky it en download Ref FIS00L Safety Information Scenius CONSIGNES...

Page 3: ...RATION 2 x 183102 805 LAM00I fitted into fixture 1 90 9 0 9 0 9 0 LOCKED UNLOCKED PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 2 3 Packing contents Fig 1 4 5 4 5 45 4 5 45 UNLOCKED LOCKED ...

Page 4: ...ed on the floor resting on special rubber feet on a truss or on the ceiling or wall WARNING with the exception of when the projector is positioned on the floor the safety cable must be fitted Cod 105041 003 available on request This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base ...

Page 5: ...play automatically returns to rest status It should be noted than when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled CONTROL PANEL 1 2 Dmx Address Warning Message Fixture ID 8 Connecting to the control signal line DMX Fig 7 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impeda...

Page 6: ...ily activate the display and thus access the settings Once the required operations have been carried out the display will switch off again after a wait time of 30 seconds USING THE MENU 1 Press F once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set the operating options Informations ...

Page 7: ...leasing Pan and Tilt movements Refer to the instructions in the UNPACKING AND PREPARATION section Opening the head covers Fig 10 Closing the head covers Fig 11 1 4 Turn 1 4 Turn 1 2 1 2 1 4 Turn 2 1 CLICK 10 11 MAINTENANCE Continue ...

Page 8: ...pened with any detergent liquid for cleaning glass to remove the dirt from the reflectors from the lenses and filters It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cleaning of internal parts Restoring lubrication of all parts subject to friction using lubricants specifically sup...

Page 9: ...9 SCENIUS SPOT 1 4 3 2 13 Cleaning of the filters Fig 13 Continue ...

Page 10: ...10 SCENIUS SPOT 1 2 1 2 1 2 Upper Side Lower Side Upper Side 14 Extraction of the effect modules Preliminary operations Fig 14 ...

Page 11: ...11 SCENIUS SPOT 1 2 3 Lower Side 4 Upper Side 15 Extraction of the effect modules Preliminary operations Fig 15 Continue ...

Page 12: ...ction of the effect modules Fig 16 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 14 15 16 17 and 18 in reverse order ...

Page 13: ...n of the effect modules Fig 17 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 14 15 16 17 and 18 in reverse order Continue ...

Page 14: ...ide 18 Extraction of the effect modules Fig 18 IMPORTANT Grasp the modules using the support structure and not the details which could get damaged Insertion of the effect modules Repeat the operations indicated in Fig 14 15 16 17 and 18 in reverse order ...

Page 15: ...soaked in alcohol and dry it with a clean dry cloth CAUTION Fast lamp ON OFF cycles for example 10 minutes ON 10 minutes OFF will reduce the lamp life ATT200 001 is the part number of a CP tool that could help you to take off the lamp from the fixture Lamp regulation Fig 21 To centre the lamp turn the three adjusting screws as shown in the figure Flat reflector or kit C61601 Standard reflector or ...

Page 16: ...iginal gobos have a special coating designed specifically to resist to the high temperatures The rotating gobo wheel only use dichroic glass gobos it is not possible to use metal gobos In case of multilayer gobo it is important to mount them on the gobo wheel 2 the one farest from the lamp For more information contact Claypaky Bearing group replacement Fig 22 22 Gobo orientation Fig 24 The picture...

Page 17: ...oval Fig 25 This product contains a rechargeable lithium iron tetraphosphate battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 9 1 2 5 3 4 6 7 8 LiFePO4 25 ...

Page 18: ...US SPOT OPTIONAL ACCESSORIES 26 C61603 Static Gobo Wheel The Static Gobo is an accessorie that can be fitted inside the fixture instead of the Animation Disk remember to set the correct Option on the User Menu ...

Page 19: ... Forced ventilation with fans and heat sink Body Aluminium structure with plastic cover Two side handles for transportation Device locking PAN and TILT mechanisms for transportation and maintenance Working position Any Working Position Hanging system with fast lock omega clamps 1 4 turn on the base Effects section Linear 0 100 Dimmer CMY System Linear CTO Fast Stop Strobe effect N 1 Colour Wheel w...

Page 20: ...r disconnected Incorrect addressing Fault in the electronic circuits Lenses or reflector broken Dust or grease deposited Check the power supply voltage Replace the lamp See instructions Replace the cables Check addresses see instructions Call an authorised technician Call an authorised technician Clean see instructions CLAYPAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 Fax 3...

Reviews: