HY B-EYE K25 TEATRO

Switching on the projector

- Fig. 8

Press the switch. The projector starts resetting the effects. At the same time, the following information scrolls on the display:

        

                                Model                                      Firmware                             xxx (Fixture ID)                     System errors

                                                         HY B-EYE                               Version X.X.X                      Dmx Address xxx                 E: .........................

                                                         K25 TEATRO                          Date - Hour                                                                        W: .........................

On conclusion of resetting in case of absence of the dmx signal, Pan and Tilt move to the “Home” position (Pan 128 bit - Tilt 128 bit). The control panel
(Fig. 8) has a display and buttons for the complete programming and management of the projector menu. The display can be in one of two conditions:
rest status and setting status. When it is in the rest status, the display shows the projector’s DMX address and the Fixture ID address (if set). 

During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status.
It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the

F

key will be cancelled.

1

2

Dmx Address

Warning Message

Fixture ID

 

 

 

 

8

Connecting to the control signal line (DMX)

- Fig. 7

Use  a  cable  conforming  to  specifications  EIA  RS-485:  2-pole  twisted,  shielded,  120Ohm  characteristic  impedance,  22-24  AWG,  low  capacity.  Do  not  use
microphone cable or other cable with characteristics differing from those specified. The end connections must be made using XLR type 3/5-pin male/female
connectors. A terminating plug must be inserted into the last projector with a resistance of 120Ohm (minimum 1/4 W) between terminals 2 and 3.

IMPORTANT:

The wires must not make contact with each other or with the metal casing of the connectors. The casing itself must be connected to the

shield braid and to pin 1 of the connectors.

 

 

 

 

 

 

 

 

 

 

SIGNAL

SCREEN

DMX 512

5 PIN

1

2

3

4

5

SIGNAL

SCREEN

1

3

2

DMX 512

3 PIN

SIGNAL
SIGNAL

Mains

6

7

Connecting to the mains supply 

- Fig. 6

Continue  

3.3 Connecting the control signal line: DMX / Art-Net

3.4 Switching on the fixture and basic SetUp

Summary of Contents for CL3015

Page 1: ... meet your expectations and requirements INDEX Page Contents 2 1 Safety information 3 2 Unpacking and preparation 4 3 Installation and start up 4 3 1 Installing the fixture 4 3 2 Connecting to manis supply 5 3 3 Connecting the control signal line DMX Art Net 5 3 4 Switching on the fixture and basic SetUp 7 4 Maintenance 7 4 1 Maintenance and Caution 8 4 2 Battery removal 9 4 3 Opening the covers 1...

Page 2: ...olgendem Link auffindbar www claypaky com Ref FIS01I Safety Information HY B EYE series INFORMACIONES DE SEGURIDAD IMPORTANTE Claypaky recomienda leer detenidamente y conservar la información de seguridad relativa a este producto Además está disponible una versión digital de la misma en el siguiente enlace www claypaky com Ref FIS01I Safety Information HY B EYE series CONSIGNES DE SÉCURITÉ IMPORTA...

Page 3: ...ATRO 4 5 4 5 45 4 5 45 90 9 0 9 0 9 0 UNLOCKED LOCKED PAN Mechanism Lock and Release every 90 Fig 2 TILT Mechanism Lock and Release every 45 Fig 3 2 3 Packing contents Fig 1 2 x 183102 805 1 2 UNPACKING AND PREPARATION ...

Page 4: ...truss or on the ceiling or wall WARNING with the exception of when the projector is positioned on the floor the safety cable must be fitted Cod 105041 003 available on request This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base 3 INSTALLATION AND START UP 3 1 Installing the fixture 3 2 Connecting to manis supply ...

Page 5: ...ed than when this condition occurs any possible value that has been modified but not yet confirmed with the Fkey will be cancelled 1 2 Dmx Address Warning Message Fixture ID 8 Connecting to the control signal line DMX Fig 7 Use a cable conforming to specifications EIA RS 485 2 pole twisted shielded 120Ohm characteristic impedance 22 24 AWG low capacity Do not use microphone cable or other cable wi...

Page 6: ...ily activate the display and thus access the settings Once the required operations have been carried out the display will switch off again after a wait time of 30 seconds USING THE MENU 1 Press F once Main Menu appears on the display 2 Use the UP B and DOWN C keys to select the menu to be used Setup Setup Menu To set the setting options Option Option Menu To set the operating options Informations ...

Page 7: ...t depends on various factors such as the amount of the effects and the quality of the working environment air humidity presence of dust salinity etc It is recommended that the projector undergoes an annual service by a qualified technician for special maintenance involving at least the following operations General cleaning of internal parts Restoring lubrication of all parts subject to friction us...

Page 8: ...RO 1 3 5 4 6 2 Battery removal Fig 11 This product contains a rechargeable battery To preserve the environment please dispose the battery at the end of its life according to the regulation in force 11 4 2 Battery removal ...

Page 9: ...9 HY B EYE K25 TEATRO 1 3 4 2 12 Opening the covers Fig 12 4 3 Opening the covers ...

Page 10: ...st the entry of solid bodies larger than 12mm 0 47 No protection against the entry of liquids NOISE LEVEL Min 35 0 dBA background 32 5 ELECTRONICS Long life auto charging buffer battery Preset color and graphic effect macros Function reset controllable from a central control unit Menu driven internal self test function Ethernet ready with RJ45 socket Display backlit black and white graphic LCD dis...

Page 11: ...xhausted or defective Signal transmission cable faulty or disconnected Incorrect addressing Fault in the electronic circuits Lenses broken Dust or grease deposited Check the power supply voltage Call an authorised technician Replace the cables Check addresses see instructions Call an authorised technician Call an authorised technician Clean see instructions 6 CAUSE AND SOLUTION OF PROBLEMS ...

Page 12: ...CLAYPAKY S p A Via Pastrengo 3 b 24068 Seriate BG Italy Tel 39 035 654311 www claypaky com IST022 001 EN Rev 0 06 2020 ...

Reviews: