background image

SUBMERSIBLE PUMPS 

OWNERS MANUAL

• INSTALLATION • OPERATION • TROUBLE SHOOTING •

For any assistance or after sales service call Claytech on our toll free number

 1300 798 022.

Please have a look at further quality Claytech products at 

www.claytech.com.au

DIRTY WATER 

VORTEX PUMPS

BVP

PROVORT 540

PROVORT 500

VORT 510

PROSUB 6/9

FILTERED 
GREY WATER

CLEAN WATER

BLUESUB 15

BLUEDIVER

BLUESUB 6

CL_SUB.OM_03.2012

• INSTALLATION • OPERATION • TROUBLE SHOOTING •

For any assistance or after sales service call Claytech on our toll free number

 1300 798 022.

Please have a look at further quality Claytech products at 

www.claytech.com.au

BRISBANE

26 French Avenue,  
Brendale, Qld, 4500

1300 798 022

F

   07 3881 2780

MELBOURNE

24 Healey Rd, 
Dandenong South, Vic, 3175

T  

03 9706 9922

F

   03 9706 9533.

CONTACT US

T

   1300 798022

sales@claytonengineering.com.au

Summary of Contents for PROSUB 6

Page 1: ...OSUB 6 9 FILTERED GREY WATER CLEAN WATER BLUESUB 15 BLUEDIVER BLUESUB 6 CL_SUB OM_03 2012 INSTALLATION OPERATION TROUBLE SHOOTING For any assistance or after sales service call Claytech on our toll free number 1300 798 022 Please have a look at further quality Claytech products at www claytech com au BRISBANE 26 French Avenue Brendale Qld 4500 T 1300 798 022 F 07 3881 2780 MELBOURNE 24 Healey Rd D...

Page 2: ...s when doing any maintenance work gloves protective eye wear etc Periodically it is advisable to make sure that no dirt leaves sand etc has accumulated in the collection pit It is absolutely necessary to protect pump from freezing If the temperature falls below the freezing point remove the pump from the liquid and store it in a safe place where it cannot freeze Clayton Engineering warrant this pr...

Page 3: ... application where a high head is required These pumps can handle water temperature up to 35 C Submersible pumps with float are not suitable for continuous operation Problem Possible Cause Solutions Pump delivers little or no water a suction screen on some models could be clogged a Clean suction screen b Air bubble in the pump body b submerged pump should be tilted and gently shaken with discharge...

Page 4: ...st be stopped by either the float switch or turning off the power switch The pump must never be allowed to run dry Never leave the pump in operation when the delivery pipe is clogged The pump must be placed in a stable position inside a collection pit or in the lowest part of the place where it is to be installed All pumps except the ProSub6 9 have an adjustable float switch which starts and stops...

Reviews: