4.0 Accessories
5.0 Operating the device
•The aim of this section is to give a brief overview necessary to operate the device and give some proposal
how to solve most normal problems occurring during operation of the device.
Information for all LED error codes can be found in section 6.0 LED Code description.
Combi devices can operate in 3 modes:
Inverter mode
• Energy is taken from the battery, inverted to 230VAC delivered at output connector (grey Neutrik).
Charger mod
e
• The charger switch on automatically when a public grid or an AC generator (185-265VAC) is present at the
AC input connector (blue Neutrik), a relay bypass the supplied AC voltage to the output (grey Neutrik). At the
same time some of the energy (from grid or generator) goes to recharge the battery bank.
Back up mode
• In case of black out of AC public grid, the device will switch over automatically to inverter function and the
connected equipment will still run powered by the battery.
•
Important: the inverter section must be switched on!
Inverter section:
Switch ON the inverter
• Push down ON/OFF power switch for approximately. 2 seconds
both blue and red LED will light
.
• After 2 seconds red LED stops and the power switch can be released.
• The blue LED will flash to indicate start up sequence
•
Blue LED lights and 230VAC is present.
Note: If the battery is discharged, then the red LED will continue to light, recharge battery and try again!
Note:
The fan is running at full speed while the power supply is starting up for acoustic detection of the fan!
COMBI Accessories List
No.
Description
a.
AC output connector, type Neutrik NAC3FCB ( Grey )
b.
Phoenix DATA connector: MSTB 2.5 / 3-ST-5.08 - Green
c.
AC input connector , type Neutrik NAC3FCA ( Blue )