Charger section:
Charge current adjust
• The charge current can be adjusted by the potentiometer on the front panel top from 0A up to maximum
rated charge current.
• See recommended charge current table in section
5.2
Charge Current Setting
for correct adjustment.
Charge characteristic setup
• Future option!
Activate the charger
• The charger section will automatically switch on regardless of the ON/OFF power switch status, when 185-
265VAC is connected to the AC input (blue Neutrik)
Note: If the inverter is switched OFF, the charger will operate at even lower voltage than 185VAC,
down to
110VAC is in this mode is accepted
But with reduced charge current!
Note: If AC was connected and then removed (short charge time), the inverter can be restarted even if the
battery is still empty!
Charge power reduction
• 2300W (10A) from the AC grid should not be exceeded! The charger reduces automatically the charge
current if the total power exceeds 2300W (charge power + load power)
Note: the regulation is slow in order to allow load peak currents, without disturbing the charging!
Important: The device has a build in fuse – see FUSING section -, do not exceed this limit!
Boost charging
• Fast flashing green LED, the charger delivers full charge current to the battery
Top charging
• Slow flashing green LED, the charge current is reduced in order not to exceed max battery voltage
allowed.
Fully charged battery
• Continuously light green LED
Deactivate the charger
• Remove AC, charging will stop.
Note: If the inverter was activated (ON) there will be 230VAC at the grey output connector (discharging)