background image

14

0

PS

U communication timeout

Cont

act y

our de

aler f

or ser

vice

14

1

PS

U communication timeout

Cont

act y

our de

aler f

or ser

vice

14

2

PS

U doe

s not w

ork as e

xpected

Cont

act y

our de

aler f

or ser

vice

230 V

A

C

Err

or code

De

scription

Solution

150

230V

AC Output o

verloaded

230V

AC output is o

verloaded. L

oad err

or

151

230V

AC Output pe

ak curr

ent dur

ation too long

230V

AC output is o

verloaded. L

oad err

or

152

230V

AC Output pe

ak curr

ent too high

230V

AC output is o

verloaded. L

oad err

or

153

PE/N r

ela

y f

ailur

e

Cont

act y

our de

aler f

or ser

vice

154

PE/N r

ela

y f

ailur

Cont

act y

our de

aler f

or ser

vice

155

Ov

erload timer f

or A

C output running o

verload err

or ma

y soon occur

230V

AC output is o

verloaded. L

oad err

or

156

AC Output not w

orking as e

xpected

230V

AC output is o

verloaded. L

oad err

or

A

C Input

Err

or code

De

scription

Solution

20

0

AC char

ging curr

ent too high

Turn off the LP

S II, w

ait 5 seconds, then turn it on b

y holding do

wn the tw

o po

w

er buttons f

or 10 seconds. If r

est

ar

t doe

not eliminate the err

or

, cont

act y

our de

aler f

or ser

vice

.

20

2

Internal high v

olt

age f

ault

Turn off the LP

S II, w

ait 5 seconds, then turn it on b

y holding do

wn the tw

o po

w

er buttons f

or 10 seconds. If r

est

ar

t doe

not eliminate the err

or

, cont

act y

our de

aler f

or ser

vice

.

20

3

230V

AC Output o

verloaded

Turn off the LP

S II, w

ait 5 seconds, then turn it on b

y holding do

wn the tw

o po

w

er buttons f

or 10 seconds. If r

est

ar

t doe

not eliminate the err

or

, cont

act y

our de

aler f

or ser

vice

.

204

Tr

ansf

er r

ela

y err

or

Cont

act y

our de

aler f

or ser

vice

20

5

Tr

ansf

er r

ela

y err

or

Cont

act y

our de

aler f

or ser

vice

20

6

230V

AC v

olt

age fr

om the mains is too lo

w

.

230V

AC char

ge is too lo

w

. Check plug or tr

y another sock

et. 

207

230V

AC v

olt

age fr

om the mains is too high. 

230V

AC char

ge is too high. Check plug or tr

y another sock

et.

208

AC Input gener

al err

or

Cont

act y

our de

aler f

or ser

vice

Summary of Contents for LPS II 1500-1 kWh

Page 1: ...Manual and safety instructions English The LPS II range ...

Page 2: ... it has been fully charged Charge only within the specified limits Make sure the LPS is switched off when moving and installing Do not mount the Lithium Power Supply upside down or on the side Check if the Lithium Power Supply has been damaged during transport Do not series or parallel connect lithium power supplies Do not leave exposed to weather Do not cover or block the fan or air intake to ens...

Page 3: ...tifications compliance 5 Safety 5 Basic operation 6 13 Error codes 14 17 Warranty 18 Copyright 19 Device overview 19 Specifications 20 3 Introduction All information and instructions have been prepared in accordance with current standards industry guidelines and our many years of experience Function overview Energy saver AC 6 Adjustable AC charging 7 DC shutdown delay 7 Adjustable DC charging 8 Ju...

Page 4: ...um Power Supply requires trained personnel in accordance with ADR RID and IMDG exceptions may apply to private and service transport check with the relevant authority For air transport IATA the packaging must comply with P965 The original packaging complies For shipping defective batteries contact your dealer for more information Maintenance Minimum maintenance is required for the LPS II to perfor...

Page 5: ...on 10 RoHS Directive 2011 65 EU EN 63000 2018 E marking E5 10R 06 0448 Safety 230 V AC input protected with 16 A fuse non replaceable 230 V AC output protected by residual current circuit breaker 30 mA 13 A can be replaced by Clayton Power or an authorised service provider DC input protected with 50 A midi fuse can be replaced by Clayton Power or an authorised service provider DC output protected ...

Page 6: ... No load Energy saver no load is an energy saving function that automatically shuts down the LPS II unit if the battery has no load The factory setting is 1 hour It is possible to set the timer or disable it Press OK to go to menu Select 230VAC output Select Energy Saver No load and press OK Use the arrows in the Energy Saver window to change the time or set to zero to turn off the function Press ...

Page 7: ...it according to a set time To set or disable the timer Press OK to go to menu Select 12VDC output Select Shutdown Delay and press OK Use the arrows in the Shutdown Delay window to change the time or set to zero to turn off the function Press OK to activate the selected option Status Operation status On Off Power W att Voltage V olt Current A mps Functions Shutdown time delay Time Energy saver Thre...

Page 8: ...elect 12VDC Output Select Set Reference Voltage and press OK Use the arrows in the Set Reference Voltage window to choose between Auto 12V or 24V Press OK to activate the selected option The selected voltage can be viewed from the DC Charging menu under Selected Voltage Set Current In Set Current you can change current load which allows you to adapt the number of amps to external fuses in the inst...

Page 9: ...olar panel can deliver without load The LSP II unit will find this point itself if you do not want to enter a value Press OK to go to menu Select Solar Select Self learning OC Voltage and press OK Use the arrows in the Self learning OC Voltage window to change the maximum number of volts from 15V to 50V Press OK to activate the selected option Self learning MPPT Voltage MPPT stands for Maximum Pow...

Page 10: ... Energy meter Temperature I O voltage Functions Error codes Display About Battery Status The Battery Status category shows a snapshot picture of device status and performance Operation Status Standby Standby On Remaining Operation Time remaining with current load Current Capacity Percent Power W Watt Voltage V Volt Current A Amps Temperature 0C Celsius Cell 1 V Volt Cell 2 V Volt Cell 3 V Volt Cel...

Page 11: ...rminal V Volt C2 terminal V Volt Error Codes Warnings errors will be listed under Error Codes Warnings and errors will disappear from the list when they are resolved Press OK to go to menu Select General Select Error Codes The full error code list can be found here in the user manual under the Error Codes category Display To change the backlight go to the Display menu You can decide if it should b...

Page 12: ...rows in the Parameter Protection window to select the desired code After each number press OK to move to the next number Press OK to activate the selected option Locked parameters will have a key icon Each time you want to change one of the locked parameters enter the self selected code The code for all parameters will be turned off for 60 seconds before the device requires it again To change dele...

Page 13: ...uals as well as tips and tricks for different installations and uses Operation via Remote Charging It is possible to read if the device is charging and from which source This is by a diode lighting up from one of the three charging options 230V 12V 12V Boost Power ON OFF To activate the LPS II press the desired voltage 230V 12V or both On correct start up a green diode will light according to the ...

Page 14: ...e with lower ambient temperature 8 9 A temperature sensor is broken Contact your dealer for service M12 data error Error code Description Solution 11 IO Remote is overloaded or short circuited Unplug and check plug and cable for damage 12 IO DATA is overloaded or short circuited Unplug and check plug and cable for damage 13 IO Front is overloaded or short circuited Unplug and check plug and cable ...

Page 15: ...mperature 58 One or more cells are overheating Allow the device to cool or place at a lower ambient temperature 59 One or more cells are overheated Allow the device to cool or place at a lower ambient temperature 60 Total battery voltage too low Volts Charge battery Solar Error code Description Solution 70 Solar overvoltage Check if the installation is correct and does not exceed the max voltage o...

Page 16: ...mbient temperature 124 DCDC Voltage A too high Provide lower 12VDC voltage to charge the device 125 DCDC Voltage B too high Turn off the LPS II wait 5 seconds then turn it on by holding down the two power buttons for 10 seconds If restart does not eliminate the error contact your dealer for service 126 DCDC current A too high Turn off the LPS II wait 5 seconds then turn it on by holding down the t...

Page 17: ... 200 AC charging current too high Turn off the LPS II wait 5 seconds then turn it on by holding down the two power buttons for 10 seconds If restart does not eliminate the error contact your dealer for service 202 Internal high voltage fault Turn off the LPS II wait 5 seconds then turn it on by holding down the two power buttons for 10 seconds If restart does not eliminate the error contact your d...

Page 18: ...r marine applications without the agreement of Clayton Power Modification or repair of the device without written approval from Clayton Power Reverse polarity extensive overload general misuse carelessness wear ingress of liquids water oil acid or other foreign bodies lightning over or under voltage electromagnetic noise interference etc Use of warranty service To obtain warranty service contact t...

Page 19: ... 9 Serial number 10 Fault current circuit breaker 11 230 output Schuko plug 12 Air cooling front Rear 13 Air cooling rear 14 DC OUT 15 DC IN 16 M12 Remote 17 M12 Data 18 C1 D 19 C2 Solar 20 Type plate 21 AC OUT 22 AC IN Dept Technical reference Created by Approved by Document type Document status Title DWG No Rev Date of issue Sheet 06 05 2021 1 1 000418 SubAssembly Mads Lauenborg 11 9 10 1 2 12 3...

Page 20: ...A 90 A DC output voltage 10 14 4 V DC 10 14 4 V DC 10 14 4 V DC DC output charging current continuous 90 A 90 A 90 A DC output discharge current continuous 180 A 180 A 180 A DC output discharge current 1 min 270 A 270 A 350 A Solar panel input charging power max 400 W 400 W 400 W Solar panel input voltage 15 50 V DC 15 50 V DC 15 50 V DC Solar panel input charging current max 15 A 15 A 15 A Input ...

Reviews: