Menu: 12 VDC Charging
Status:
Operation status: On/Off
Power:
(W)att
Voltage: (V)olt
Current: (A)mpere
Selected Voltage: 12V/24V
Functions:
Jumpstart functionality:
Active/Inactive
Jumpstart:
On/Off
Set Reference Volt: Auto/12V/24V
Set Current:
(A)mps
Jumpstart
Press "OK" to go to menu - Select "DC Charging" - Select "Jumpstart" and press "OK".
Move to space between Jumpstart and press “OK”. After activating Jumpstart, it will be possible to
start the vehicle after about 4 minutes.
8
Set Reference Voltage
In the function "Set Reference Voltage" it is possible to change the Volt DC load. The factory
setting will be Auto, where the device detects the charge voltage itself. In some cases, the LPS II
may have difficulty detecting the charge correctly, hence it can be changed manually to 12V or
24V.
Press "OK" to go to menu - Select "12VDC Output" - Select "Set Reference Voltage" and press "OK".
Use the arrows in the Set Reference Voltage window to choose between Auto, 12V or 24V. Press
"OK" to activate the selected option.
The selected voltage can be viewed from the "DC Charging" menu under Selected Voltage.
Set Current
In "Set Current" you can change current load, which allows you to adapt the number of amps to
external fuses in the installation.
Press "OK" to go to menu - Select "DC Output" - Select "Set Current" and press "OK".
Use the arrows in the "Set Current" window to change the maximum number of amps from 0A to
45A. Press "OK" to activate the selected option.
Jumpstart functionality
Jumpstart functionality is a safety feature that must be enabled before it is
possible to use the jumpstart function.
Press "OK" to go to menu - Select "DC Charging" - Select "Jumpstart Functionality"
You can use the arrows in the Jumpstart Functionality window to choose whether the function
should be active or inactive. Press "OK" to activate the selected option.