Warranty Terms

Clayton Associates, Inc. guarantees its manufactured products against defects in materials or workmanship and will either repair or replace 

all parts that prove defective under normal use during the lifetime of the products. The warranty period shall commence from the date of paid 

invoice.
This warranty does not cover (a) repairs due to normal wear, accident, neglect, misuse, or use other than as indicated in the instruction booklet 

(b) products manufactured by third parties and distributed by Clayton (c) wear items such as bearings, rotor blades, regulators, valve stems, 

levers, shrouds, guards, O‑rings, seals, gaskets, motor brushes, and other wearable parts.

Repair within the Continental US

During the first 90 days of the warranty period, Clayton will provide parts and labor to the customer’s site at no charge or pay freight costs 

associated with returning the products for repair to a Clayton selected service location and repair the product at no charge. Clayton personnel 

will determine the best way to repair the product.
Past 90 days, Clayton will provide parts to the customer’s site at no charge or the customer may ship the product to a Clayton selected service 

location at customer’s expense and Clayton will repair the product at no charge and provide return shipping.

Repair Outside the Continental US

Clayton will provide parts to the customer’s site at no charge or the customer may ship the product to a Clayton selected service location at 

customer’s expense and Clayton will repair the product at no charge and provide return shipping.

Limitation of Liability

Clayton shall not in any event be liable for any damages, loss of production time or profits, whether based on contract, warranty, negligence, 

strict liability or otherwise, including without limitation any consequential, incidental or special damages, arising with respect to the equipment 

or its failure to operate.
Clayton Associates, Inc. makes no other warranty or representation of any kind, except that of title, and all other warranties, express or implied, 

including warranties of merchantability or fitness for any particular purpose, are hereby expressly disclaimed.

LIMITED LIFETIME WARRANTY TERMS AND CONDITIONS

Summary of Contents for Warthog WGX-115G-0

Page 1: ...nd this manual before operating your air tool A HEPA Filter must be installed in this vacuum at all times If this vacuum is used to collect hazardous material appropriate personal protective equipment may be required Any alteration to this equipment by a third party will nullify its warranty WartHog WGX Power Head Electric HEPA Industrial Vacuum Models WGX 107G 0 WGX 107G 1 WGX 115G 0 WGX 115G 1 W...

Page 2: ...ssMadeSimple com Sales JClayton com Page 2 Important Safety Instructions 3 Applications Environments 4 What s In the Box 4 Specifications Requirements 4 Getting Started 5 Before Each Use 7 Bag Filter Change 7 Pre Filter Change 8 HEPA Filter Change 9 Illustrated Parts Breakdown 10 Limited Lifetime Warranty Terms And Conditions 14 EC Declaration of Conformity 15 ...

Page 3: ...h as cigarettes matches or hot ashes Do not use without all filters in place Do not allow to be used as a toy Close attention necessary when used by or near children Use extra care when cleaning on stairs EARTHING GROUNDING INSTRUCTIONS This appliance must be earthed grounded If it should malfunction or breakdown earthing grounding provides a path of least resistance for electric current to reduce...

Page 4: ...ags filters and other components These instructions assume you have both a power head and an appropriate Clayton vacuum tank Refer to the instruction manual included with the vacuum tank for additional information PHYSICAL Weight TBD lbs TBD kg Dimensions Diameter x Height 17 5 x 12 in 44 5 x 30 5 cm Sound Level 67 dBA POWER CONSUMPTION Power Rating 2 hp Power Consumption 12 5 A 120 Vac 7 5 A 220 ...

Page 5: ...ship in separate boxes 2 Unbox the vacuum power head 3 Visually inspect the power head to verify that no parts are missing or damaged 4 Familiarize yourself with the power head 5 Power Head Vents NEVER BLOCK THE POWER HEAD VENTS NEVER WRAP THE POWER CORD AROUND THE POWER HEAD VENTS GETTING STARTED WGX 0_002 Power Cord Filter Adapter HEPA Wire Lock Hex Standoff HEPA Wire Lock Hex Standoff Power Swi...

Page 6: ...3 Install a new HEPA filter Holding the power head on its side screw the new HEPA filter onto the filter adapter Verify the white inner ring of the HEPA filter is fully seated against the underside of the power head If it is not rotate it clockwise until fully seated Refer to the instructions included with the HEPA cable lock to install the cable lock 4 Attach the power head Position the power hea...

Page 7: ...he power head from the tank Lift the power head and the attached HEPA filter off the tank using the top handle Carefully place the power head on the floor avoid damaging the HEPA filter 3 Remove the filter bag Grasp the cardboard collar of the bag filter and slide it off the inlet port on the vacuum tank Holding your hand over the opening on the bag lift the bag out of the tank Dispose of the bag ...

Page 8: ...power head Unlatch the power head from the tank Lift the power head and the attached HEPA filter off the tank using the top handle Carefully place the power head on the floor avoid damaging the HEPA filter 3 Remove the pre filter The pre filter is wrapped around the HEPA filter and secured with Velcro Find the seam and carefully peel the Velcro apart Dispose of the pre filter according to company ...

Page 9: ... set aside Remove the HEPA filter from the box and remove it from the plastic bag 4 Remove the old HEPA filter Holding the power head on its side cut the HEPA cable lock and remove it Unscrew the HEPA filter from the filter adapter Dispose of the HEPA filter according to company policy 5 Install a new HEPA Filter Holding the power head on its side screw the new HEPA filter onto the threaded filter...

Page 10: ...0ft Yel 5B 900 153H000X 30 Cord 1 5MM 3 Conductor H05VVF 30ft Black 6 900 M14R3 Molex Receptacle 14 ga 3 Position 7 900 M14S Molex Socket Terminal 14 ga 8 900 SW SPDT 01 Switch Rocker Rect 20A 120V SPDT On Off On Black 9 930 027 Handle Carry Flex Rubber 10 FE103212 HZSM Z Hex Standoff 10 32 MF x 3 4 in SS 11 NE10320608 HNSZ Nut 10 32 Nylon Lock SS Short 12 RE0620 SDSSS Z Rivet Blind 3 16 x 0 625 S...

Page 11: ...WGX 0 603 WGX 1 Sheet 2 of 4 Seq Item No Description 1 911 803 1 Handle Cap Sound Control Foam 2 911 803 2 Exhaust Baffle Sound Control Foam 3 911 803 3 Enclosure Top Sound Control Foam 4 911 803 4 Base Ring Sound Control Foam 5 911 803 5 Motor Plate Sound Control Foam 6 911 803 6 Enclosure Foam 1 Sound Control 6 911 803 7 Enclosure Foam 2 Sound Control 6 911 803 8 Enclosure Foam 3 Sound Control 1...

Page 12: ...otor Assembly 220V 2 600 WF 1364F Washer Fiber 13 64 ID x 3 8OD 3 601 021 Filter Adapter WartHog 4 601 121 Mesh Disc 3 in Diameter 5 605 310B16 HH Vac Head Base 16in SS Black 6 911 011 Gasket Filter Adapter 7 911 Q6600 220T Conical Motor Gasket Silica Gel 8 FE103208 HZSM B Hex Standoff 10 32 MF x 1 2 SS With Bore 9 NE10320615 HNSZ Nut 10 32 Nylon Lock SS High 10 NE16201420 HNSZ Nut 1 4 20 Hex Lock...

Page 13: ...1 Sheet 4 of 4 Seq Item No Description 1A 600 Q6600 220T Motor Bypass 120V 13 5A 2HP 120CFM 1B 600 Q6600 223T Motor Bypass 220 240V 7 5A 2 3HP 120CFM 2 605 310C HH Vac Head Motor Collar SS 3 911 04G08 Grommet 7 32 ID 1 2 OD 4 911 803 5 Motor Plate Sound Control Foam 5 SE101212 PPSS Z Screw Sheet Metal 10 X 750 Phillips SS 6 WE133203 RFS Z Washer 203ID X 500OD 047H Round Stainless Steel WGX 0_007 4...

Page 14: ...selected service location and repair the product at no charge Clayton personnel will determine the best way to repair the product Past 90 days Clayton will provide parts to the customer s site at no charge or the customer may ship the product to a Clayton selected service location at customer s expense and Clayton will repair the product at no charge and provide return shipping Repair Outside the ...

Page 15: ...anufactured in compliance with the essential requirements and other relevant provisions of the following applicable directives Machinery Directive 2006 42 EC The Electromagnetic Compatibility Directive 2004 108 EC Compliance has been obtained by application of the following standards EN ISO 12100 2010 11 EN 60335 1 2012 A13 excluding 25 6 EN 60335 2 69 2012 specifically Annex AA Requirements for v...

Page 16: ...X 0 WGP XXXX 0 WTX XXXX 0 WTP XXXX 0 WGX XXXX 1 WGP XXXX 1 WTX XXXX 1 WTP XXXX 1 Tank Models 107G 107T 115G 115T 205G 205T 215G 215T With serial numbers ranging from WH0000001 through WH9999999 Were tested to verify the integrity of the HEPA filter and the assembled machine Test Procedure The test was performed using an aerosol generator and a photometer The system was challenged with 18 microlite...

Page 17: ...THIS PAGE IS INTENTIONALLY BLANK ...

Page 18: ...or Warranty Contact Clayton Associates Inc 1650 Oak Street Lakewood New Jersey 08701 P 1 732 363 2100 F 1 732 364 6084 www DustlessMadeSimple com Sales JClayton com Clayton products are proudly made in the USA ...