7
Auto Mode:
Depending on the temperature, the humidifier sets the optimum humidity
a. The device determines the temperature in the surrounding of the device (margin of about
2-5 degrees difference from the actual room temperature).
b. The optimal humidity levels with different temperatures are taken from the data base of the
device.
c. The device works at maximum power until the optimal humidity is achieved.
d. If the optimal humidity is achieved, then the humidification will stop.
e. The device checks the accordance of the temperature level and the humidity level every 10
minutes.
Baby Mode:
When the
Baby Mode
is activated, the device turns on the function of warm mist & UV-Light
and starts to achieve 55% humidity at maximum power. If the 55% humidity is achieved, then
the humidification will stop. The device checks the humidity level every 10 minutes.
Health Mode:
When the
Health Mode
is activated, the device turns on the function of warm mist & UV-Light,
it will calculates the optimal humidity and starts to achieve it at maximum power.
The optimal humidity in Health Mode is calculated as in the Auto Mode, the only difference is
that the device add 5% to the result.
Example:
Optimal humidity in Auto Mode = 50%, Optimal humidity in Health Mode = 50 + 5 = 55%
When the optimal humidity level is achieved, then the humidification will stop.
The device checks the accordance of the temperature level and the humidity level every 15
minutes.
Temperature of the air, degrees Celsius
Humidity %
19 and lower
65
20-21
60
22-23
55
24-25
50
26-27
45
28-29
40