Coil Tube Boiler Operator's Manual: Models CB-200-CTB, CB-350-CTB, and CB-500-CTB
A-2
CB-200-CTB Hydronic Specifications
NOTE:
These specifications apply for each CTB unit or coil.
•
Water flow through the boiler:
• Coil Dry Weight: 189 lbs.
15 GPM at 20 -22 ft. of head (pressure)
• System operating pressure: 12 to 22 psi
•
20
o
F
temperature rise (
ΔΤ
)
• Standard relief valve setting: 30 psi
•
ASME coil length: 112 ft. long, 1" diameter steel • Relief valve capacity: 550 MBH
tubing made to Sch. 40 pipe size
• Heating surface: 38.7 sq. ft.
•
Coil Volume: 5 Gallons
• Factory Recommended Boiler Circulator:
TACO 0011
Burner Technical Specifications
CB-350-CTB Hydronic Specifications
NOTE:
These specifications apply for each CTB unit or coil.
•
Water flow through the boiler:
• Coil Dry Weight: 359 lbs.
25 GPM at 18-20 ft. of head (pressure)
• System operating pressure: 12 to 22 psi
•
20
o
F
temperature rise (
ΔΤ
)
• Standard relief valve setting: 30 psi
•
ASME coil length: 158 ft. long, 1-1/4" diameter
• Relief valve capacity: 710 MBH
steel tubing made to Sch. 40 pipe size
• Heating surface: 68 sq. ft.
•
Coil Volume: 12.3 Gallons
• Factory Recommended Boiler Circulator:
B&G PL36
B&G PL55 (over 20 ft. of head)
CB-500-CTB Hydronic Specifications
NOTE:
These specifications apply for each CTB unit or coil.
•
Water flow through the boiler:
• Coil Dry Weight: 530 lbs.
37 GPM at 22 ft. of head (pressure)
• System operating pressure: 12 to 22 psi
•
20
o
F
temperature rise (
ΔΤ
)
• Standard relief valve setting: 30 psi
•
ASME coil length: 195 ft. long, 1-1/2" diameter
• Relief valve capacity: 970 MBH
steel tubing made to Sch. 40 pipe size
• Heating surface: 97 sq. ft.
•
Coil Volume: 20.63 Gallons
• Factory Recommended Boiler Circulator:
TACO 2400-50/2
Model
CB-200-CTB
CB-350-CTB
CB-500-CTB
Burner
CB-525-S2
CB-551-H3
CB-551-H5
Ignition Transformer
Carlin
14,000 Volts
Carlin
14,000 Volts
Carlin
14,000 Volts
Nozzle
Delavan 9-5
Delavan 9-5
Delavan 9-28
Burner Motor
1/10 HP 3000 rpm
(w/ Centrifugal Switch)
1/10 HP 3000 rpm
(w/ Centrifugal Switch)
1/10 HP 3000 rpm
(w/ Centrifugal Switch)
Burner Motor Rotation
CCW shaft end
CCW shaft end
CCW shaft end
Compressed Air
Requirements
2.0 CFM
@25 PSI
2.5 CFM
@25 PSI
2.5 CFM
@25 PSI
Oil Primary Control
Carlin Oil
Primary 402
(w/ Interrupted Ignition)
Carlin Oil
Primary 502
(w/ Interrupted Ignition)
Carlin Oil
Primary 502
(w/ Interrupted Ignition)
Heater Element in
Preheater Block
400 Watts
400 Watts
500 Watts
Air Pressure Switch
MPL 808
MPL 808
MPL 808
Heater Thermostat
140
o
F
140
o
F
160
o
F
Summary of Contents for CB-200-CTB
Page 2: ......
Page 4: ......
Page 20: ...CoilTubeBoilerOperator sManual ModelsCB 200 CTB CB 350 CTB andCB 500 CTB 1 12 ...
Page 24: ...CoilTubeBoilerOperator sManual ModelsCB 200 CTB CB 350 CTB andCB 500 CTB 2 4 ...
Page 72: ...CoilTubeBoilerOperator sManual ModelsCB 200 CTB CB 350 CTB andCB 500 CTB 5 6 ...
Page 78: ...CoilTubeBoilerOperator sManual ModelsCB 200 CTB CB 350 CTB andCB 500 CTB 6 6 ...
Page 82: ...CoilTubeBoilerOperator sManual ModelsCB 200 CTB CB 350 CTB andCB 500 CTB 7 4 ...
Page 86: ...CoilTubeBoilerOperator sManual ModelsCB 200 CTB CB 350 CTB andCB 500 CTB 8 4 ...
Page 108: ...CoilTubeBoilerOperator sManual ModelsCB 200 CTB CB 350 CTB andCB 500 CTB 11 8 ...
Page 117: ...CoilTubeBoilerOperator sManual ModelsCB 200 CTB CB 350 CTB andCB 500 CTB A 9 ...
Page 140: ...CoilTubeBoilerOperator sManual ModelsCB 200 CTB CB 350 CTB andCB 500 CTB A 32 ...
Page 148: ...CoilTubeBoilerOperator sManual ModelsCB 200 CTB CB 350 CTB andCB 500 CTB C 2 ...