Operator's Manual: Models CB-3500 & CB-5000
5-3
8.
Activating the Pump
NOTE:
The CB-3500 and CB-5000 furnaces feature a priming switch which is mounted on the
left-hand side of the electrical junction box on the front of the furnace cabinet. The priming switch has
two positions:
•
PRIME (switch is in the UP position / orange indicator light is ON):
this is used only
for pump priming. When the switch is in the UP position, the pump circuit is activated for
priming. The pump will continue to run as long as the switch is in this position. The oil
primary control circuit is de-activated so the burner cannot run while the switch is in the UP
position.
•
BURNER (switch is in the DOWN position):
this is used for normal burner operation.
When the switch is in the DOWN position, the burner controls the operation of the pump.
The pump will only run while the burner is running.
a. Refer to Figure 5B to locate the priming switch.
b. Turn the priming switch to the prime (UP) position. The pump should immediately start running.
Priming the Metering Pump (continued)
Figure 5B - Locating the Pump Priming Switch
I88808-D
OIL PUMP
PRIMING SWITCH
OIL PUMP
PRIMING LIGHT
Summary of Contents for CB-3500 series
Page 2: ......
Page 18: ...Operator s Manual Models CB 3500 CB 5000 1 10 ...
Page 36: ...Operator s Manual Models CB 3500 CB 5000 3 16 ...
Page 68: ...Operator s Manual Models CB 3500 CB 5000 5 6 ...
Page 74: ...Operator s Manual Models CB 3500 CB 5000 6 6 ...
Page 94: ...Operator s Manual Models CB 3500 CB 5000 9 10 ...
Page 102: ...Operator s Manual Models CB 3500 CB 5000 10 8 ...
Page 107: ...Operator s Manual Models CB 3500 CB 5000 A 5 ...
Page 126: ...Operator s Manual Models CB 3500 CB 5000 A 24 ...
Page 134: ...Operator s Manual Models CB 3500 CB 5000 C 2 ...