1. 

In the event a manual dispense needs to be 

initiated, identify the pump/chemical to be 

dispensed and it’s override control button.

2. 

Press and hold the button to dispense.

3. 

When dispense volume has been obtained, 

release the button to stop the dispense.

Maintenance

1. 

Check hose/tubing for secure connections

2. 

Ensure there are no air line leaks

3. 

Verify air regulator settings (consult ALX controller 

manual for recommended regulator settings)

NOTE: 

Check valves connect to push buttons 

front to back / bottom to top (i.e. the front check 

connects to the bottom button and so on).

Summary of Contents for ALX-ABB

Page 1: ...USER MANUAL English Original Instructions Updated 03 24 21 MODEL ALX ABB Chemical Allocation Manual Air Button Box ...

Page 2: ... of the following User accessibility Distance to ALX controller tower Distance to Devices and pumps Connections for air 2 Using appropriate mounting hardware not included to install Installation NOTE For more information on Controller installation requirements and configuration please consult the User Manual for the included ALX Controller for model specific requirements ...

Page 3: ...ines as necessary 2 Connect air lines from solenoid devices to the air inlet check valves 3 Connect air lines to the chemical pumps for each corresponding solenoid output Consult the diagram below for more information Installation cont FROM AIR REGULATOR TO ALX TOWER OR ADDITIONAL ABB IF APPLICABLE CAN SO 4 SOLENOID OUTPUT ALX ABB 4 AO FROM AIR REGULATOR TO ALX TOWER OR ADDITIONAL ABB IF APPLICABL...

Page 4: ...hemical to be dispensed and it s override control button 2 Press and hold the button to dispense 3 When dispense volume has been obtained release the button to stop the dispense Maintenance 1 Check hose tubing for secure connections 2 Ensure there are no air line leaks 3 Verify air regulator settings consult ALX controller manual for recommended regulator settings NOTE Check valves connect to push...

Page 5: ...OTH 10 SS M1630 ABB FRONT PLATE M1631 ABB REAR PLATE P1181 ENCLOSURE FIBOX AR1086CHSSL P1202 QUICK FIT ELBOW 3 8 NPT X 3 8 TUBE P1214 QUICK FIT TEE 3 8 P1215 QUICK FIT REDUCER 3 8 X 1 4 P1219 QUICK FIT ADAPTER 3 8 NPT x 3 8 TUBE P1271 3 8 OD POLYETHYLENE TUBING NATURAL P1316 QUICK FIT PLUG 3 8 P1535 VALVE STEM 1 4 NPT X 3 8 QUICK FIT QTY BREAKS AT 50 100 P1536 VALVE PUSHBUTTON ACTUATOR GREEN ENP Q...

Reviews: