Page 1: ...USER MANUAL English Original Instructions Updated 02 11 21 MODEL BLX 100W Single Manual BootScrubber Wet ...

Page 2: ...act of cleaning agent with skin and eyes If contact occurs see MSDS sheet for further first aid measures 2 Follow safety instructions of chemical manufacturer MSDS 3 Always follow plant and OSHA guidelines about the use of hygiene equipment 4 All personnel using this unit must be familiar with the information contained in this manual Follow all installation and maintenance instructions 5 Always we...

Page 3: ...e desired location use a level to make sure the unit is stable and level in all directions Make sure the location is a flat surface 4 Using the 4 mounting brackets near each corner securely fasten the unit to the floor with appropriate hardware for the given material i e concrete anchors and bolts as shown in Figures 3 1 and 3 2 5 Dosing of sanitizing chemicals into water supply can be accomplishe...

Page 4: ...t as shown in Figure 4 1 Installation continued Fig 4 1 Inserting and attaching Foot Plate Plumbing 1 Connect the water regulator on the Venturi to the water supply line regulator thread 1 2 2 Using 3 8 OD polyethylene tubing or similar connect the sanitizer solution to be used to the Venturi s hose barb as shown below NOTE A back flow preventer must be installed in the water line for this unit Ch...

Page 5: ...as shown in Figure 5 2 2 Once unlocked the brushes can be removed for cleaning by slipping them out from their holders Plumbing continued 3 Using the push to connect fitting connect the Venturi system to the BLX s water line located under the unit near the foot plate Figure 5 1 4 Test the system by stepping on the footplate to engage the unit and begin spraying 5 Adjust the solution output as nece...

Page 6: ...the process with the second boot 5 If boots are extremely dirty it may be necessary to scrub them multiple times Cleaning and Wash Down 1 Shut off water supply to unit and depressurize water lines 1 Remove the Foot Plate and brushes from the unit 2 Brushes and Foot Plate can be washed individually in a COP tank or wash machine 3 The frame can be washed down by conventional means Operation The foll...

Page 7: ...BLX 100W Manual Page 7 of 9 Updated 02 11 21 USER MANUAL BLX 100W READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT General Installation Operation Appendix Notes ...

Page 8: ...LATE BLX MANUAL M1399 SPRAY BAR BLX MANUAL P1047 VENTURI INJECTOR 3 8 SS P1100 PIPE HEX NIPPLE 3 8 SS P1102 PIPE NIPPLE 1 4 CLOSE SS P1103 PIPE TEE 1 4 SS P1104 PIPE ELBOW 1 4 X 90 SS P1107 PIPE ELBOW STREET 1 4 SS P1108 PIPE CAP 1 4 SS P1196 PIPE COUPLER 1 4 P1211 QUICK FIT 1 4 NPT X 3 8 TUBE P1219 QUICK FIT 3 8 NPT X 3 8 TUBE P1248 LABEL SLIP HAZARD P1302 PIPE NIPPLE 1 4 X 3 SS P1338 METERING TI...

Page 9: ...BLX 100W Manual Page 9 of 9 Updated 02 11 21 USER MANUAL BLX 100W READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT General Installation Operation Appendix Appendix B Dimensions ...