background image

BLX-100W Manual  Page 6 of 9

Updated: 02/11/21

USER MANUAL: BLX-100W

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

General Use

Prior to use - ensure brushes and foot plate are 

secured, the system itself properly installed, and that 

water is both turned on and flowing to the unit's 

spray bars. To verify water/sanitizer supply; step on 

the Foot Plate to initiate water/sanitizer flow. Before 

operating the unit, ensure solid footing and 

use both 

hands on the handrail for support.
1. 

To begin operation, step up onto the Foot Plate 

and grip the support handrail.

2.  Place one boot in the unit.
3. 

Push the boot back and forth multiple times so 

every part makes contact with the brushes.

4. 

Once the first boot is clean, remove it and repeat 

the process with the second boot.

5. 

If boots are extremely dirty, it may be necessary to 

scrub them multiple times.

Cleaning and Wash-Down

1. 

Shut off water supply to unit and depressurize 

water lines.

1.  Remove the Foot Plate and brushes from the unit.
2.  Brushes and Foot Plate can be washed, 

individually, in a COP tank or wash machine

3. 

The frame can be washed down by conventional 

means.

Operation

The following maintenance procedures are 

recommended for normal use.  Units which see a 

high amount of daily use should be inspected more 

frequently as necessary.

Weekly:

• 

Inspect brushes for damage or wear.  

•  Check for missing or deformed bristles.
• 

Inspect plumbing/water lines for damage

• 

Ensure solid mounting to floor.

Monthly:

• 

Check all fasteners to ensure they are tight.

•  Ensure warning labels and decals are present 

and in good condition.

• 

Inspect valve for damage

Quarterly:

• 

Inspect structure for cracked welds or bent 

components.

Maintenance

Summary of Contents for BLX-100W

Page 1: ...USER MANUAL English Original Instructions Updated 02 11 21 MODEL BLX 100W Single Manual BootScrubber Wet ...

Page 2: ...act of cleaning agent with skin and eyes If contact occurs see MSDS sheet for further first aid measures 2 Follow safety instructions of chemical manufacturer MSDS 3 Always follow plant and OSHA guidelines about the use of hygiene equipment 4 All personnel using this unit must be familiar with the information contained in this manual Follow all installation and maintenance instructions 5 Always we...

Page 3: ...e desired location use a level to make sure the unit is stable and level in all directions Make sure the location is a flat surface 4 Using the 4 mounting brackets near each corner securely fasten the unit to the floor with appropriate hardware for the given material i e concrete anchors and bolts as shown in Figures 3 1 and 3 2 5 Dosing of sanitizing chemicals into water supply can be accomplishe...

Page 4: ...t as shown in Figure 4 1 Installation continued Fig 4 1 Inserting and attaching Foot Plate Plumbing 1 Connect the water regulator on the Venturi to the water supply line regulator thread 1 2 2 Using 3 8 OD polyethylene tubing or similar connect the sanitizer solution to be used to the Venturi s hose barb as shown below NOTE A back flow preventer must be installed in the water line for this unit Ch...

Page 5: ...as shown in Figure 5 2 2 Once unlocked the brushes can be removed for cleaning by slipping them out from their holders Plumbing continued 3 Using the push to connect fitting connect the Venturi system to the BLX s water line located under the unit near the foot plate Figure 5 1 4 Test the system by stepping on the footplate to engage the unit and begin spraying 5 Adjust the solution output as nece...

Page 6: ...the process with the second boot 5 If boots are extremely dirty it may be necessary to scrub them multiple times Cleaning and Wash Down 1 Shut off water supply to unit and depressurize water lines 1 Remove the Foot Plate and brushes from the unit 2 Brushes and Foot Plate can be washed individually in a COP tank or wash machine 3 The frame can be washed down by conventional means Operation The foll...

Page 7: ...BLX 100W Manual Page 7 of 9 Updated 02 11 21 USER MANUAL BLX 100W READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT General Installation Operation Appendix Notes ...

Page 8: ...LATE BLX MANUAL M1399 SPRAY BAR BLX MANUAL P1047 VENTURI INJECTOR 3 8 SS P1100 PIPE HEX NIPPLE 3 8 SS P1102 PIPE NIPPLE 1 4 CLOSE SS P1103 PIPE TEE 1 4 SS P1104 PIPE ELBOW 1 4 X 90 SS P1107 PIPE ELBOW STREET 1 4 SS P1108 PIPE CAP 1 4 SS P1196 PIPE COUPLER 1 4 P1211 QUICK FIT 1 4 NPT X 3 8 TUBE P1219 QUICK FIT 3 8 NPT X 3 8 TUBE P1248 LABEL SLIP HAZARD P1302 PIPE NIPPLE 1 4 X 3 SS P1338 METERING TI...

Page 9: ...BLX 100W Manual Page 9 of 9 Updated 02 11 21 USER MANUAL BLX 100W READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT General Installation Operation Appendix Appendix B Dimensions ...

Reviews: