6
Figure 2.2.1
1
. 24 VDC Power Supply Jack
2
. Compressed Air Supply, use 1/4” tubing
3
. Air Supply to Alcohol Dispenser, use 5/32” tubing
4
. Return from Alcohol Dispenser, use 5/32” tubing
2.2
Air Supply
Connect a 1/4” air supply hose to the fitting found on the back of the Automatic Fitting
Inserter. The air supply should be free of moisture and contaminates and supplies
100-
120
psi. It is important to have the ability to shut off the air pressure or disconnect
from the main air line. A quick-connect coupling or ball valve is recommended.
Figure 2.1.1
The air supply will need to be off or disconnected when manually cycling the pin set
actuation air cylinder.
Safety Note: Keep hands clear of moving parts when connecting or disconnecting the air supply.
The jaws may move suddenly. Failure to do so may result in serious injury.
Ensure that the High Pressure Regulator is set between 80-120 psi. (shown in Figure
2.2)
The unit must have a minimum of 80 psi to operate properly.
Ensure that the Low Pressure Regulator is set between 20-40 psi. The Low Pressure
Regulator must always be set between 20-40 psi for the machine to function properly.
Caution: Do not set above 40 psi, as high pressure can cause premature wear to
the machine and/or damage the unit.
1
2
3
4
Summary of Contents for CRD610
Page 3: ...3 1 0 General Product Safety Information ...
Page 23: ...23 11 0 Parts List ...