J-PRO-22 Alum Guide Rev 0021622 Page | 5
The pump is designed to pull Alum solution out of a solution tank and pump a precise amount of Alum
into a pipeline under pressure.
Right out of the box, this is a dual-voltage (110/220) pump.
There are several ways to wire the pump such that it triggers
when there is water flow.
The well pump is controlled by your pressure switch.
Choosing one of the ways outlined below, the J-Pro-22 pump
will be installed so that it powers up and injects Alum when the
well pump and motor are turned on via the pressure switch.
1.
You can wire it to your well pressure switch, using a
dedicated electrical wall outlet.
2.
You can install a flow switch and plug the J-Pro22 into that.
3.
You can cut the plug and wire direct to pressure switch. Note that the
ground wire is yellow color, brown and blue are hot wires.
Wire To Pressure Switch Option