Installer's Manual: Clean Burn Air Compressors
3-9
Preparing the Furnace Cabinet (Furnace Models CB-3500 and CB-5000)
1.
Refer to Figures 3A/3D and your Furnace Operator's Manual for an overview of furnace assembly
(refer specifically to information on the installation of the mounting/stabilizer brackets and
the all-thread rods).
2.
According to the Furnace Operator's Manual, install the mounting and stabilizer brackets which
hold the all-thread rods in place.
3.
Install all-thread rods through the channels in the furnace cabinet as described in the Furnace
Operator's Manual. Use washers and double nuts to securely lock the all-thread rods in position.
NOTE:
The air compressor will be installed on one of the forward all-thread rods as illustrated
in Figure 3D.
Mounting the Air Compressor (Furnace Models CB-3500 and CB-5000)
CAUTION:
The compressor must be securely mounted as described in this section. Ensure that
all nuts and bolts are firmly tightened.
1.
Refer to Figures 3A and 3D.
2.
While facing the burner side of the furnace, install the air compressor on the front right all-thread rod
using the two U-bolts and nuts provided. Position the mounting bracket a few inches below the
stabilizer bracket as shown in Figure 3D.
Mounting the Air Compressor
(Boiler Models CB-200-CTB / CB-350-CTB / CB-500-CTB)
CAUTION:
The compressor must be securely mounted as described in this section. Ensure that
all nuts and bolts are firmly tightened.
1.
Refer to the previous illustrations. The air compressor configuration on a boiler is similar to that shown
on the furnace illustrations.
2.
Install the air compressor on an adjacent wall at least (2) two feet from the boiler
(due to temperature requirements).