Copyright ©2006 by Cleanfix Cleaning Systems Inc., 465 West Main St., Wyckoff, NJ 07481.
All rights reserved. Content is subject to change.
7
TROUBLESHOOTING (cont.)
Symptom: Weak
vacuum
Problem:
Worn out lid gasket
Solution:
Replace lid gasket (# 12062)
Problem:
Defective vacuum motor (noisy bearing, carbon brush sparking burn out armature & worn
out carbon brush)
Solution:
Replace vacuum motor (# 12210) and motor gasket (# 12062.1)
Problem:
Lint accumulation on vacuum filter screen.
Solution:
Clean filter screen. If screen is defective, replace screen (# 12076.1)
Symptom:
Waste pump out will not start or run
Problem:
GFCI reset button popping out only when waste pump is turned on indicates damage to
pump seal or internal cable connection leak.
Solution:
Have a qualified pump service shop repair the pump. If the pump is defective, replace
pump (# 12305)
Problem:
Defective rocker switch.
Solution:
Replace black DPDT rocker switch (# 12276) or lighted rocker switch
(#
12027)
Problem:
Debris under float switch, float not moving freely, defective float switch.
Solution:
Clean debris. Have a qualified shop check pump if it still won’t work
properly.
Symptom:
Waste pump motor overheats and trips overload /GFCI
Problem:
Defective capacitor, motor shorted, impeller or seal locked,
Solution:
Have a qualified shop check pump (# 12305). Replace if necessary.