TROUBLESHOOTING (cont.) 

 
Symptom: Weak 

vacuum

 

 

Problem: 

Worn out lid gasket 

Solution: 

Replace lid gasket (# 12062) 

 

Problem: 

Defective vacuum motor (noisy bearing, carbon brush sparking burn out armature & worn 
out carbon brush) 

Solution: 

Replace vacuum motor (# 12210) and motor gasket (# 12062.1)

 

 
Problem: 

Lint accumulation on vacuum filter screen. 

Solution: 

Clean filter screen. If screen is defective, replace screen (# 12076.1)  

 

Symptom: 

Waste pump out will not start or run

 

 

Problem: 

GFCI reset button popping out only when waste pump is turned on indicates damage to 
pump seal or internal cable connection leak. 

Solution: 

Have a qualified pump service shop repair the pump. If the pump is defective, replace 
pump (# 12305) 

 

Problem: 

Defective rocker switch.  

Solution: 

Replace black DPDT rocker switch (# 12276) or lighted rocker switch  

  (# 

12027) 

 

Problem: 

Debris under float switch, float not moving freely, defective float switch.  

Solution: 

Clean debris. Have a qualified shop check pump if it still won’t work  

  

 

properly. 

 

Symptom: 

Waste pump motor overheats and trips overload /GFCI 

 

Problem: 

Defective capacitor, motor shorted, impeller or seal locked, 

Solution: 

Have a qualified shop check pump (# 12305). Replace if necessary. 

 
 

Summary of Contents for Pelican FloodVac HBP20FV

Page 1: ...loodVac unit Model HBP20FV It provides necessary operation and maintenance instructions 20 GAL SINGLE VAC FLOOD VACUUM READ AND FOLLOW ALL INSTRUCTIONS WARNINGS AND CAUTIONS BEFORE AND WHEN USING THIS EXTRACTOR All information and specifications printed in this manual are current at the time of printing However because of Cleanfix s policy of continual product improvement we reserve the right to m...

Page 2: ...push the RESET button more than twice Have a qualified service person check out the unit A GFCI does not protect against circuit overloads and short circuits Do not run waste pump dry as it will damage the seals The vacuum is intended for WET pick up only Do not use as a dry vacuum Do not operate the machine where explosive vapors or flammable materials exist Do not use where oxygen and anesthetic...

Page 3: ...her flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire GROUNDING METHODS This electric equipment is for use on a nominal 120 volt circuit and has a grounded plug that looks like the plug illustrated in Fig A A temporary adaptor that looks like the adaptor illustrated in Fig B C may be used to connect this plug to ...

Page 4: ...switch lighted when it is on 3 1 1 2 vacuum hose adaptor 4 Drain valve for recovery tank Pull T Handle up to open Drain valve must be closed after each use Install drain elbow upon receipt of the unit 5 Latches to motor compartment Latches must be secured when using the machine 6 GFCI Ground Fault Circuit Interrupter red RESET button black TEST button Occasionally press the TEST button then RESET ...

Page 5: ... St Wyckoff NJ 07481 All rights reserved Content is subject to change 5 FUNCTIONAL PARTS AND ACCESSORIES cont Rear view 9 1 1 2 discharge hose adaptor A discharge hose must be connected at the discharge adapter when discharge pump is turned on 10 Power cord 9 10 ...

Page 6: ...mpty out recovered waste into a bucket Remove lint bag and turn it inside out to clean Rinse the recovery tank with clean water Replace lint bag TROUBLESHOOTING Symptom No power to the machine Problem GFCI RESET button popped out Solution Lift cover and push RESET red button If the RESET button pops out immediately the second time do not attempt to RESET again Have a qualified service technician c...

Page 7: ... pump out will not start or run Problem GFCI reset button popping out only when waste pump is turned on indicates damage to pump seal or internal cable connection leak Solution Have a qualified pump service shop repair the pump If the pump is defective replace pump 12305 Problem Defective rocker switch Solution Replace black DPDT rocker switch 12276 or lighted rocker switch 12027 Problem Debris un...

Page 8: ...hes wheels casters glides clutches cords filters filter bags gaskets hoses rectifiers switches float switches valves squeegees bearings pulleys relays actuating cables wheels tires vacuum cleaner attachments The purchaser is assured that meticulous care has been exercised in the selection assembling and testing of these parts and components before shipping No warranty is extended for machine finis...

Reviews: