TROUBLE-SHOOTING
22
VACUUM SYSTEM
CAUTION:
1. DISCONNECT POWER CORDS FROM THE OUTLET BEFORE DOING ANY MAINTENANCE WORK.
2. WHEN ELECTRIC POWER IS ON PROTECT YOURSELF FROM ELECTRIC SHOCK & HEAT
ETC...
PROBLEM
POSSIBLE CAUSE
HOW TO REPAIR
PROBLEM
POSSIBLE CAUSE
HOW TO REPAIR
Vacuum motor on with little or no
1. Lid is not properly closed
1. Close the lid
vacuum or suction at wand/
2. Drain hose/valve not connected/
2. Connect hose or close optional drain
upholstery tool
closed
valve
3. Hose or wand clogged
3. Clean hoses and wand
4. Accumulated dirt on the ball float
4. Clean or replace the filter
cage and filter
5. Worn out lid gasket
5. Replace the gasket
6. Lint and dirt build-up on wand
6. Clean the wand
7. Damaged vacuum hose
7. Replace
8. Loose or no vacuum hose
8. See authorized repair person
connection inside the extractor
9. Foriegn object accumulated in
9. See authorized repair person
vacuum fans
Vacuum motors run intermittently
See authorized repair person
No water from the jet
1. Extractor not plugged in (or circuit
1. Plug in working outlet
breaker off)
2. Switch is not turned on (bad switch?)
2. Turn the switch on. See authorized
repair person for new switch
3. Empty solution tank
3. Fill the solution tank with water
4. The hose is not connected properly
4. Connect hose properly
Water or foam coming out from
1. Over foaming of water in reovery
1. Put defoamer in the recovery tank
exhaust
tank
or put it in the end of vacuum hose
wtih vacuum motor running
2. Elbow fitting in recovery tank pointing
2. Point elbow away from ball-float
wrong direction (i.e. pointed toward
cage
the ball-float cage)
3. No ball-float cage
3. Install ball-flat
4. Too much water in the recovery tank
4. Drain the recovery tank